FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page F-62.2

PDF page 660 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 660
AC 27-1B · F-62.2Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

   6/23/23                                             AC 27-1B, Chg 9


       (5) Energy storage systems that have the potential to emit corrosive fluids,
explosive gasses, or toxic gasses will require a design scheme to contain, drain, or vent
these fluids or gasses, to meet the requirements of § 27.1353(c). This design scheme
must not expose structure or adjacent equipment to corrosive fluids, as required by
§ 27.1353(c), or allow explosive or toxic gasses to accumulate to hazardous levels, as
required by § 27.1353(b).

       (6) Energy storage systems that are susceptible to thermal runaway should
include a sense and control capability to prevent such an event or a design to safely
contain or vent heat and pressure. Designs for energy storage systems with potential for
thermal runaway must prevent an uncontrolled cascading failure that results in a
hazardous condition, to meet the requirements of § 27.1353(d).


    b. Procedures.


        (1) General. Chapter 11 of AC 43.13-1B, Acceptable Methods, Techniques, and
Practices—Aircraft Inspection and Repair, includes considerable guidance regarding the
installation of electrical systems (routing, separation, typing, clamping, j-box
installations, etc.). The following areas are overlooked in many cases, and special
emphasis should be placed on them during the compliance inspection of the rotorcraft:


               (i) Feeder wires from the rotorcraft’s generators and energy storage systems
should be routed separately from utilization system wiring.

                (ii) Generator field wiring should be routed separately from generator output
wiring. This should begin at the generator and continue to the voltage regulator.


         (2) Energy Storage System Installation.


                (i) Installation approval of an energy storage system consists of two parts.
One part is the approval of the energy storage system performance specifications that
meet the rotorcraft requirements and the other part is the actual installation of the
energy storage system into the rotorcraft. The following methods of showing compliance
can be demonstrated by a combination of tests and analysis.

                  (ii) Approval of the energy storage system for installation is dependent on
rotorcraft requirements for the installed equipment and operations.





                           Page F - 62.2

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →