Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page F-30.18

PDF page 608 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 608
AC 27-1B · F-30.18Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

                                               AC 27-1B, Chg 9
6/23/23


             TH MAR = 275 - (275 + (100 - 90)) = 10° F


        At 5,000 feet:


             TH MAR = 275 - (270 + (82 - 80)) = 23° F


        At 10,000 feet:


             TH MAR = 275 - (285 + (64 - 60)) = 6° F


        At 15,000 feet:


             TH MAR = 275 - (274 + (46 - 42)) = -3° F


        At 20,000 feet:


             TH MAR = 275 - (270 + (28 -20)) = -3° F


 Since TH MAR comes out negative at the 15,000- and 20,000-foot points, the generator
  fails. It will be necessary for the applicant to reduce the maximum load current, improve
 cooling, or otherwise change the design to ensure the generator is operating within its
 approved temperature limit of 275° F.

             5. In most cases, the equipment is laboratory tested to minimum
  temperatures as severe as that of the rotorcraft’s maximum certified altitude on a
  minimum temperature day. Therefore, unless equipment minimum temperature is
  affected by refrigeration or other temperature reducing environments, actual installed
  instrumented minimum temperature tests are unnecessary. If low temperature
  evaluation is necessary for the installed equipment, the following is an acceptable
  method:


        TOAT MIN = Minimum outside air temperature at which temperature tests are
        conducted.

         TMIN = Minimum temperature to which the installed equipment has been tested in
        the laboratory.



                               Page F - 30.18

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →