This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.
The source, within reach.
Search within this AC, jump to a source page, or download the complete saved publication.
This extraction supports search. Read the original page for complete notation and layout.
9/30/99 AC 27-1B
a fire hazard is not created during either normal or emergency service, there should be
complete, rapid drainage and ventilation capability present for each part of the rotorcraft
powerplant installation and any other designated fire zone which utilizes flammable fluid
or vapor carrying components. As a minimum, the routing, drainage, and ventilation
system should accomplish the following:
(1) It should be effective under normal and emergency operating conditions.
(2) It should be designed and arranged so that no discharged fluid or vapor will
create a fire hazard under normal and emergency operating conditions.
(3) It should prevent accumulation of hazardous fluids and vapors in engine
compartments and other designated fire zones.
b. Definitions. Drip Fence. A physical barrier that interrupts the flow of a liquid on
the underside of a surface, such as a fuel tank, and allows any leaked liquid to drip from
the surface away from hazardous locations to a safe external drain.
c. Procedures. The design of flammable fluid and gas systems running through
engine compartments and other designated fire zones should have a thorough hazard
analysis performed early during certification that is updated periodically as design
changes dictate. The hazard analysis should identify and quantify all normal and
emergency service failures that could result in leakage of fuel, flammable fluids and
vapors. Once these potential hazards are identified and quantified, appropriate design
features, such as drains, drip fences and vents, that minimize or eliminate the hazard
should be provided. These means should be analyzed, tested, or a combination as
necessary, to ensure that their size, flow capacity, and other design parameters are
adequate to rapidly remove hazardous fluids and vapors safely away from the rotorcraft
under normal and emergency flight conditions. Typically a venting or draining system
should be designed to a 3-to-1 flow capacity margin over the probable worst case leak
to which it could be subjected. Adverse effects such as clogging and surface tension
flow reduction should be accounted for in design. Testing, including flight testing, using
inert fluids or vapors may be necessary for proper design certification. In some
instances it may be appropriate to include ventilation and drainage tests when the
aircraft is parked.
AC 27.1189. § 27.1189 (Amendment 27-23) SHUTOFF MEANS.
a. Explanation.
(1) This section establishes the requirements for controlling hazardous
quantities of flammable fluids which flow into, within, or through designated fire zones.
(2) When any shutoff valve is operated, any equipment, including a remaining
engine, which is essential for continued flight, cannot be affected.
Page E - 127
Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.
Aerospace Consulting / Engineering perspective
Start with the certification basis and the function.
Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.
1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.
A focused review, an agreed assessment package or ongoing support alongside your team. We can agree the relevant inputs and scope in the initial conversation.
This opens your email application.
Start a conversation
Tell us about your programme, the system you are developing and the support you need.
We can agree a focused use-case review, a defined evidence package or ongoing programme support.
This opens your email application.
Specialist aerospace expertise
Aerospace Consulting is led by Hussein Khimji, an FAA Designated Engineering Representative in systems and equipment, with a focus on system safety, flight controls and avionics.
We work with aircraft developers and systems suppliers to connect technical decisions, safety assessments and certification evidence.
This is the proposed introduction. The full About page will add your approved biography and associate expertise.
Systems engineering & development assurance
Tell us about the aircraft or system, its intended function, stage of development and the support you need.