FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page E-126

PDF page 546 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 546
AC 27-1B · E-126Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

AC 27-1B, Chg 4                                                       3/31/2014

compartment or other fire zone fires. In some cases fuel or flammable fluid components
must be located in an engine compartment or other designated fire zone. In these
cases, an equivalent safety finding (which considers the design, construction, materials,
fuel lines, fittings, and controls used in the system, or system segment, contained in the
engine compartment or other designated fire zone) should be undertaken as a part of
the normal certification process.  If the level of safety provided is equivalent to that
provided by removing the system or system segment out of the engine compartment or
designated fire zone, then the design should be accepted. For fuel tanks only, isolation
is required by regulation to be achieved by use of either a firewall
(reference paragraph AC 27.1191 for Firewall Requirements) or by use of a shroud. A
shroud if used should be fireproof (see § 1.1 for definition and the definition of a Severe
Fire for further details) and should be drainable (or otherwise inspectable) to insure the
fuel tank is not leaking in service. For other flammable fluid or vapor tanks, the
regulations allow either the identical treatment previously described for fuel tanks (i.e.,
firewalls or shrouds) or, alternatively, use of an equivalent safety finding. The
equivalent safety finding, if used, can be made as part of the standard certification
process. Regulations require that the equivalent safety finding be based on system
design, tank materials, tank supports, and flammable fluid system connectors, lines, and
controls. In all cases the flammable fluids, fuels, and vapors should be sufficiently
isolated from hazardous heat fluxes during both normal and emergency operations to
prevent autoignition.

         (2) In addition, the regulations require at least one-half inch of clear airspace
between each flammable fluid or vapor tank and each firewall or shroud that isolates the
system, unless equivalent means (such as fireproof insulation) are used to prevent
hazardous heat transfer from each engine compartment or other fire zone to the
flammable fluid or vapor mass (or its container surface) at the fluid or vapor’s minimum
autoignition temperature.  If in-service structural deflections are significant, they must be
taken into account when certifying the one-half inch minimum clear airspace
requirement. For example, if a one-half inch clearance exists on the ground but in some
normal and emergency flight conditions (e.g., autorotation) the one-half inch is reduced
to one-fourth inch at a critical time (in-flight engine fire), then the design (static)
configuration should have at least a one-half plus one-fourth equals three-fourths inch
static clear airspace to insure the regulation’s intent is met. Alternatively, fireproof
insulation or additional stiffeners could be used to insure the regulation’s intent is met
(i.e., the thermal equivalent of one-half inch clearance is maintained at all times). Any
material used as insulation on or used adjacent to a flammable fluid or vapor tank,
should be certified as chemically compatible with the flammable fluid or vapor and to be
non-absorbent in case of fuel or vapor leaks. Otherwise, the material should either be
treated for compatibility and non-absorbency or not accepted.

AC 27.1187.    § 27.1187 VENTILATION AND DRAINAGE.

     a. Explanation. To ensure that any component malfunction which results in fuel,
flammable fluid or vapor leaks is safely drained or vented overboard and to ensure that



Page E - 126

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →