9/30/99 AC 27-1B
AC 27.1185. § 27.1185 (Amendment 27-11) FLAMMABLE FLUIDS.
a. Explanation. This section requires that fuel, flammable fluid, or vapor tanks,
reservoirs or collectors be sufficiently isolated from engines, engine compartments, and
other designated fire zones so that hazardous heat transfer from these areas to fuel,
flammable fluid, and vapor tanks, reservoirs, or collectors is prevented in either normal
or emergency service.
b. Definitions.
(1) Fuel or Flammable Fluid Collector. Any device such as a large valve,
accumulator, or pump that contains a significant amount of flammable fluid, fuel, or
vapor (e.g., the volume equal to 10 ounces or more of fluid).
(2) Flammable Fluid or Vapor Tank. Any fuel, flammable, fluid, or vapor tank,
reservoir, or collector.
(3) Sufficiently Isolated. Fuel, flammable fluids, or vapors in a tank, reservoir,
or collector are insulated, removed, otherwise protected or a combination such that their
worst case temperatures (the worst case measured or calculated surface temperature
of their containers) in either normal or emergency service is always 50° F or more away
from the autoignition temperature of the fuel, flammable fluid, or vapor in question.
(4) Minimum Autoignition Temperature. The temperature at a given vapor
pressure at or above which liquid fuel or fuel vapor will self combust. When determining
the minimum design value of autoignition temperature which will occur in either normal
or emergency operations, the critical, in-service combination of vapor pressure and fuel
temperature should be determined.
(5) Hazardous Heat Transfer. A total incident heat flux (a combination of
conduction, convection, and radiation, as applicable) from or in an engine compartment
or other designated fire zone, which would raise the temperature level of a flammable
fluid or fuel, their vapors, or the surface temperature of their containers to within 50° F
or less of the minimum in-service autoignition temperature. Typically, the most critical
heat transfer case to be considered is emergency service where a severe fire (see
definition) is assumed to occur in each engine compartment and each designated fire
zone on a case-by-case basis.
(6) Severe Fire. See definition in paragraph AC 27.859.
c. Procedures.
(1) The fuel, flammable fluid, and vapor system designs should be reviewed
early in certification to insure that all flammable fluid or vapor tanks are properly
identified and isolated from engines, engine compartments, and other designated fire
zones during both normal and emergency operations such as in-flight engine
Page E - 125