FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page E-124

PDF page 544 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 544
AC 27-1B · E-124Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

AC 27-1B                                                                  9/30/99

                  SUBPART E - POWERPLANT

                POWERPLANT FIRE PROTECTION


AC 27.1183.    § 27.1183 (Amendment 27-20) LINES, FITTINGS, AND
            COMPONENTS.

     a. Explanation. This section requires that any line, fitting or other component of a
flammable fluid, fuel or flammable gas system which carries, conveys, or contains the
fluid or gas in any area subject to engine fire conditions (i.e., a severe fire) must be at
least fire resistant (reference § 1.1 for definition of fire resistant and see
paragraph AC 27.859 which defines a severe fire). An exception is for flammable fluid
tanks and supports which are part of and attached to the engine or are in a designated
fire zone. These items are required to either be fireproof (see § 1.1 for definition of
fireproof and see paragraph AC 27.859 which defines a severe fire) or to be enclosed
by a fireproof shield, unless fire damage to any non-fireproof part (e.g., secondary line
or valve support) will not cause leakage of a flammable gas, flammable fluid or
otherwise prevent continued safe flight and landing of the rotorcraft. All such
components must be shielded, located, otherwise protected or a combination to
safeguard against the ignition of leaking flammable fluids or gases. Integral oil sumps
of less than 25 quarts capacity on a reciprocating engine need not be fireproof or
enclosed by a fireproof shield; however, they should be fire resistant. Most integral
sumps in this category are, by natural design and material selection, fire resistant.
Exemptions to the preceding requirements are as follows:

         (1) Lines, fittings and components already approved under Part 33 as part of
the engine itself.

         (2) Vent and drain lines (and their fittings) whose failure will not result in or add
to an operational fire hazard. In addition, all flammable fluid drains and vents must
discharge clear of the induction system air inlet and other obvious ignition hazards.

     b. Procedures. A detailed review of the design should be conducted to identify
and quantify all lines, fittings, and other components which carry flammable fluids and/or
gases and are in areas subject to engine fire conditions such as engine compartments
and other fire zones. Once these items are identified the design means of fire
protection should be selected and validated, as necessary, during certification. For
materials and devices that cannot be qualified as fireproof or fire resistant by similarity
or by known material standards, testing to severe fire conditions (see
paragraph AC 27.859 definition, AC 20-135, and AC 23-2 for detailed requirements)
should be conducted on full-scale specimens or representative samples to establish
their fireproof or fire resistance capabilities. Exceptions to these standards (as provided
in the regulatory section) should be reviewed and approved/disapproved on a
case-by-case basis during certification. Also, operational fire hazards from drains,
vents, and other similar sources should be identified and eliminated during certification.


Page E - 124

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →