FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page E-95

PDF page 513 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 513
AC 27-1B · E-95Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

9/30/99                                             AC 27-1B

carburetor parts list used during these tests becomes a requirement in the definition of
the engine/carburetor configuration.

     b. Procedures.

         (1) Seldom is testing actually accomplished at the maximum required ambient
temperature of at least 100° F at sea level lapsed 3.6° F per 1,000 feet pressure
altitude. Component and fluid temperatures must therefore be corrected to derive the
item temperature that would have been reached if the test day had matched exactly the
maximum ambient temperature day. The applicant may select a higher maximum
ambient temperature for cooling certification than the 100° F sea level hot day
prescribed. Provisions are also made for selecting a maximum ambient temperature
less than the 100° F sea level hot day for winterization installations not intended to
function at the hot day conditions.

         (2) When cooling test ambient conditions are cooler than the selected or
prescribed hot day conditions, the applicant may take advantage of cooling air or fluid
flows that would exist at hot day conditions. For example, thermostatically controlled oil
cooler flow could be set for hot day conditions.

         (3) The component and fluid temperature correction factor to be applied when
test ambients do not correspond to the hot day conditions is commonly called the
“degree-for-degree correction.”  It may be possible to justify, and the regulation allows
the application of a more refined, less conservative correction factor. A correction factor
other than degree-for-degree should be based on engineering test data.

         (4) No corrected temperatures may exceed established limits. In order to
maintain temperatures within established limits, the applicant may be willing to accept
lesser performance than the full capability of a device. For example, a starter/generator
capable of cooling under test cell conditions to 200 amperes continuous load may be
limited to a lesser value, perhaps to 150 amperes, when installed in the aircraft due to
cooling considerations. This continuous load for cooling must be equal to or greater
than the allowable continuous load designated on aircraft instruments.

         (5)  If the engine or transmission cooling system heat load is increased in any
way by rotorcraft configuration changes (affecting airflow, etc.), by other systems, by
accessories (alternators, generators, etc.), or by any other heat source or potential heat
source, then the maximum cumulative heat load from the worst-case combination of all
these sources which is possible in service must be present during the cooling tests.

      c. Thermal Limit Correction.

         (1) An important correction factor which is not discussed in the regulations, but
is frequently necessary to show the cooling adequacy required by § 27.1041, is the
thermal limit correction factor. This factor is sometimes used if, at test day conditions,



                                                       Page E - 95

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →