FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page E-37

PDF page 455 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 455
AC 27-1B · E-37Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

9/30/99                                             AC 27-1B


         (2) Section 27.952(b) provides three sets of static load factors for design and
static analysis of fuel tanks, other fuel system components of significant mass and their
installations. “Installation” is structurally defined as the fuel cell’s attachment to the
airframe and any additional local (point design) airframe structure affected significantly
by fuel cell crash loads (i.e., that would fail or deform to the extent that a fuel spill or a
ballistic hazard would occur in a survivable impact). Section 27.952(d) significantly
limits the amount of local airframe structure to be considered. The provision of load
factors by zone ensures the fuel-tight integrity necessary to minimize PCF in a
survivable impact. Unless explicitly shown by both analysis and test that the probability
of fuel leakage in a survivable impact is 1 x 10-9 or less, each tank and its installation
must be designed and analyzed to one set of these load factors. Also, as stated and
explained in the advisory material for § 27.561, the load factors specified by § 27.561(d)
are for the airframe structure surrounding the fuel cell only. The fuel cells themselves
(and any fuel system components of significant mass in the underfloor area) and their
attachments to the surrounding airframe structure are subject to the load factors of
§ 27.952(b)(3).

                  (i)    Section 27.952(b)(1) provides load factors for the design and static
analysis of fuel cells and their attachments inside the cabin volume. These load factors
are provided to prevent crash-induced fuel cell ballistics hazards to and fuel spills (that
may cause a PCF) directly on occupants from local structural failures in a survivable
impact.

                   (ii)   Section 27.952(b)(2) provides load factors for design and static
analysis of fuel cells and their attachments located above or behind the cabin volume.
These load factors are provided to prevent injury or death from a fuel cell behind or
above the occupied volume that is loosened by impact and to prevent fuel spills (which
may cause a PCF) in a survivable impact.

                    (iii)   Section 27.952(b)(3) provides load factors identical to those of
§ 27.561 for design and static analysis of fuel cells and attachments located in areas
other than inside, behind, or above the cabin volume. Since many fuel cells are located
under the cabin floor, these load factors provide fuel-tight structural protection in a
survivable impact.

               (iv)  For some crash resistant semi-rigid bladder and flexible liner fuel cell
installations, the 50-foot drop test (reference § 27.952(a)) can (with some additional
rational analysis) simultaneously satisfy both the drop test requirement and the vertical
down load factor (-NZ) requirement of § 27.952(b)(3) for the fuel cell itself and its
installation. This approach reduces the certification burden.

              (v)   For applicants that seek to substantiate the -NZ load factor
requirement of § 27.952(b)(3) using the 50-foot drop test, additional substantiation is
required for § 27.952(b)(3) (as is currently practiced) for the fuel cell under the loading
of the remaining three load factors and the remaining rotorcraft structure under the


                                                       Page E - 37

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →