Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page E-35

PDF page 453 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 453
AC 27-1B · E-35Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

9/30/99                                             AC 27-1B

        (12) Crash Resistant Fuel System (CRFS). A fuel system designed and
approved in accordance with § 27.952 that either prevents a PCF or delays the start of
a severe PCF long enough to allow escape.

        (13) As Far as Practicable. “As Far as Practicable” means that within the
major constraints of the applicant’s design (e.g., aerodynamic shape, space, volume,
major structural relocation, etc.), this standard’s criteria should be met. The level of
practicability is much higher in a new design project than in a modification project. The
engineering decisions, evaluations, and trade studies that determine the maximum level
of practicability should be documented and approved.

        (14) Fireproof. Defined in § 1.1, “General Definitions” and in AC 20-135,
“Powerplant Installation and Propulsion System Component Fire Protection Test
Methods, Standards and Criteria” dated February 6, 1990.

     d. Procedures.

         (1) Section 27.952 should be applied to all fuel system installations. Any major
design change should be reevaluated for compliance with the CRFS requirements.  It
should be noted that most standard materials and processes are acceptable for crash
resistant fuel system construction; however, magnesium, magnesium alloys, and
cadmium plated parts (when exposed to fuel) are not recommended, because of their
inherent ability to create or contribute to a post crash fire. Section 27.952(a) requires
each tank, or the most critical tank (if clearly identified by rational analysis) to be drop
tested. The tank is filled 80 percent with water and the remaining 20 percent is filled
with air (or, in the case of a flexible fuel cell, the air may be evacuated by hand and the
cell resealed). The tank openings, except for the vents, are closed with plugs (or other
suitable means) so that they remain watertight. The vents are left open to simulate
natural venting. Otherwise, the tank is flight configured. The test tanks are installed in
their surrounding structure and dropped from a height of 50 feet on a nondeformable
surface (e.g., concrete or equivalent). To be considered a valid test, the tank must
impact horizontally ±10°. The 50-foot distance is measured between the nondeformable
surface and the bottom of the tank. The ±10° attitude requirement can be ensured by
using lightweight cord or a light sling to balance the tank assembly horizontally prior to
being dropped. MIL-T-27422B shows a typical test setup. Tank attitude at impact
should be verified by photography or equivalent means. The nondeformable floor
surface should be covered by a thin plastic sheet so that any leakage is readily
detected. The tank water should be tinted with dye to make leakage and seepage
sources easy to identify. The tank (except for the vent openings) should be wrapped in
light plastic sheet to ensure that minor leakage or seepage (and its source) is detected.
Minor spillage through the open vents during the drop test is allowed. The dye should
not significantly affect the water’s viscosity or other physical properties that may reduce
or eliminate any leakage from the drop test. The nondeforming drop test surface should
be carefully reviewed. Concrete is acceptable. A fixed and uniformly supported steel
plate (loaded only in uniform compression without any springback) is acceptable.
Floors or floor coverings such as dirt, clay, wood, or sand are not acceptable. Selection


                                                       Page E - 35

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →