FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page D-125

PDF page 398 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 398
AC 27-1B · D-125Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

2/4/2016                                       AC 27-1B, Chg 7


            (v) Each quick-release device should be designed and located to allow the
pilot or a crewmember to accomplish external cargo release without hazardously limiting
the ability to control the rotorcraft during emergency situations. The flight manual
should reflect the requirement for a crewmember and the related functions.

             (vi) Section 27.865(c)(1) QRS Requirements for Jettisonable HEC
Operations.

              (A) For jettisonable HEC operations, both the PQRS and BQRS are
required to have a DAD for external cargo release. The DAD must be designed to
require two actions with a definite change of direction of movement, such as opening a
switch or pushbutton cover followed by a definite change of direction in order to activate
the release switch or pushbutton. Any possibility of opening the switch cover and
inadvertently releasing the load with a single motion is not acceptable. An additional
level of safety may also be provided through the use of Advisory and Caution
messages. For example, an advisory “ON” message might be illuminated when the
pilot energizes (but not arms) the system with a master switch. A cautionary “ARMED”
message would then illuminate when the pilot opens the switch guard. In this case, a
possible unwanted flip of the switch guard would be immediately recognized by the
crew. The switch design should be evaluated by ground or flight test. The RFM or
RFMS should contain a clear description of DAD functionality to include the associated
safety features, normal and emergency procedures, and applicable advisory and
caution messages.

              (B) The DAD is intended for emergency use during the phases of flight
that the HEC is carried or retrieved. The DAD can be used for both NHEC and HEC
operations. However, because it can be used for HEC, the instructions for continued
airworthiness should be carefully reviewed and documented. The DAD can be operated
by the pilot from a primary control or, after a command is given by the pilot, by a
crewmember from a remote location. Additional safety precautions (such as a lockwire)
should be considered for remote hoist console in the cabin. Any emergency release
function provided by a remote hoist console must also be designed to protect against
inadvertent activation during the hoist operation.  If the backup DAD is a cable cutter, it
should be properly secured, placarded and readily accessible to the crewmember
intended to use it.

              (vii) Section 27.865(b)(3)(ii) Electromagnetic Interference. Protection of the
QRS against potential internal and external sources of EMI and lightning is required.
This is necessary to prevent inadvertent load release from sources such as lightning
strikes, stray electromagnetic signals, and static electricity.

              (A) Jettisonable NHEC systems should be able to absorb a minimum of 20
volts per meter (i.e., CAT U) radio-frequency (RF) field strength per RTCA Document
DO-160.



                                                         Page D - 125

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →