AC 27-1B 9/30/99
(8) For compliance with § 27.859(h), each combustion and ventilating air
intake’s location should be identified, reviewed, and tested to ensure that no flammable
fluids or vapors can enter the heater system, ignite and create a fire. If a combustion or
ventilating air intake’s location is critical or questionable, it should be relocated,
shielded, drained, or other equivalent means provided to eliminate the potential fire
hazard. If engineering analysis and evaluation are not adequate to make an acceptable
safety finding, testing using dyed, inert, leaked fluids or vapors should be conducted.
(9) For compliance with § 27.859(i), each heater exhaust system design should
be reviewed, tested, or a combination to ensure proper compliance with § 27.1121 and
§ 27.1123 (reference AC paragraphs AC 27.1121 and AC 27.1123, respectively). Each
exhaust shroud should be sealed to ensure that leaked flammable fluids or vapors do
not contact the hot exhaust and cause a fire. The seal design should be reviewed to
ensure that the sealing material is fireproof, is chemically compatible with the relevant
fuels and vapors, is durable and is functionally adequate. If the design review is not
conclusive for compliance purposes, then the seal system should be bench tested
under pressure while undergoing critical service loads and motions to ensure no
leakage occurs. An analysis should be conducted to determine the structural effects on
the exhaust system of the worse case restricted backfire (typically a shock wave
analysis can be used to determine the peak internal pressure and, the resultant load on
the exhaust system.) If structural failure would occur, based on the analysis, either the
backfire restriction should be reduced or the exhaust design should be structurally
improved to eliminate the failure.
(10) For compliance with § 27.859(j), each heater’s fuel system design must be
reviewed to ensure that compliance with the powerplant fuel system requirements of
Part 27 that are necessary for safe operation to be achieved. An equivalent safety
finding should be made if an application is received that requests partial compliance or
non-compliance with the powerplant fuel system requirements of Part 27. The finding
should ensure that the safety intent of § 27.859(j) is achieved. Analysis, engineering
evaluation, testing, or a combination should be used to substantiate the heater fuel
system design. Heater fuel system components that, by leakage or other failures, can
induce flammable fluids or vapors into the ventilating air stream should be shrouded by
drainable, fireproof shrouds.
(11) For compliance with § 27.859(k), the drain system design should be
reviewed to identify parts that may be subjected to high temperature and parts that may
be subjected to hazardous ice accumulation in service. The high temperature parts
should be evaluated using the methods of compliance for heater exhausts (reference
paragraph AC 27.859b(9), above and paragraph AC 27.1123). Drains that would be
stopped up from ice accumulation should be protected by relocation, size, shields,
heating, or a combination to ensure hazardous fluids and vapors are properly drained
away.