9/30/99 AC 27-1B
and/or flight test work with dyed, inert fluids or vapors should be conducted to
accurately display discharge patterns.
(4) For compliance with § 27.859(d), the ventilating air duct design should be
reviewed to determine what ducts are routed through heater zones. Once this has been
determined, each duct section running through the heater zone should be made
fireproof by either using a fireproof shroud around the existing duct or by using fireproof
material for the duct wall.
(5) For compliance with § 27.859(e), any design using combustion air ducts
should be reviewed to ensure that the ducts are either made from fireproof material or
shrouded with a fireproof shroud over a safe distance (see definition). The safe
distance should be determined analytically, by test, or a combination, if the analytical
results are not conclusive. The design should be reviewed to ensure that combustion
air ducts are not connected to the ventilating air stream, except when an equivalent
safety finding can be made that shows backfires or reverse burning cannot induce
flames or fumes into the ventilating air stream under any failure condition or malfunction
of the heater or its associated components. Such a finding should require analysis,
testing, or a combination for a proper determination.
(6) For compliance with § 27.859(f), the design and installation of all standard
control components, control tubing and safety controls should be reviewed to determine
the probable points of water or ice accumulation (e.g., sumps, rough surfaces, joints,
etc.) If a design review cannot accurately determine these accumulation points, then
bench tests and flight tests should be conducted for proper determination. Once these
points are identified, the ability of the effected part (or parts) to perform its intended
function when water or ice has fully accumulated must be determined for both normal
and failure conditions. If the part (or parts) either has not lost its ability to function: has
lost only part of its ability to function; or has lost all of its ability to function; and the
entire system’s function is not impaired, then nothing further should be required.
However, if the overall system’s function is hazardously impaired or lost, as a result of
water or ice accumulation on a part (or parts), then rectifying design improvements
should be made prior to final approval. These improvements should either alter the
part’s environment (e.g., relocation, enclosure, insulation, etc.) or eliminate the
hazardous accumulation of water or ice (e.g., provide drainage, better sealing, better
location, different surface finish, etc.).
(7) For compliance with § 27.859(g), combustion heaters, if used, must have
separate, independent safety controls from their standard controls (e.g., air
temperature, air flow, fuel flow, etc.) which are remotely located in case of a heater fire,
are operable by the crew and automatically shut off the ignition and fuel supply when a
hazardous condition exists (as defined by § 27.859(g)). These separate safety controls
must comply with § 27.859(g)(1), must keep the heater off until restarted by the crew or
ground maintenance, and must warn the crew when an essential heater is automatically
shut down. The safety control system design should be thoroughly reviewed and tested
to ensure that it complies and that no hazardous failure modes exist.
Page D - 103