Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Extracted text for finding words
This extraction supports search. Read the original page for complete notation and layout.
AC 27-1B, Chg 4 12/1/2011
samples should be used in material allowable strength testing. Company standards
should be prepared, evaluated and FAA-approved early in certification (as part of the
building block process), that reflect the material property determination considerations
recommended in CMH-17 on an equal to or better than basis.
(3) The third area is the protection of structure as required by § 27.609. Protection
against thermal, humidity, and other environmental effects (e.g., weathering, abrasion,
fretting, hail, ultraviolet radiation, chemical effects, accidental damage) should be
provided, or the structural substantiation should consider the results of those effects for
which total protection is impractical. Determination and approval of worst-case or most
conservative operating limits, and damage scenarios should be accomplished.
Appropriate flammability and fire-resistance requirements should also be considered in
selecting and protecting composite structure. Usually, a threat analysis is conducted
early in the certification process that identifies the various threats and threat levels for
which protection must be provided. This data is then used to construct and submit for
approval the methods-of-compliance necessary to provide proper structural protection.
(4) The fourth area is the lightning protection requirements of § 27.610. Protection
should be provided and substantiated in accordance with analysis and with tests such
as those of AC 20-53, “Protection of Aircraft Fuel Systems Against Fuel Vapor Ignition
Caused by Lightning” and FAA Report DOT/FAA/CT-86/8. For composite structure
projects involving rotorcraft certificated to earlier certification bases (which do not
automatically include the lightning protection requirements of § 27.610), these
requirements should be imposed as special conditions. The design should be reviewed
early in the certification process to ensure proper protection is present. The
substantiation test program should also be established, reviewed and approved early to
ensure proper substantiation.
(5) The fifth area is the static strength evaluation requirements of §§ 27.305 and
27.307 for composite structure. Structural static strength substantiation of a composite
design should consider all critical load cases and associated failure modes, including
effects of environment, material and process variability, and defects or service damage
that are not detectable or allowed by the quality control, manufacturing acceptance
criteria, or maintenance documents of the end product. The static strength
demonstration should include a program of component ultimate load tests, unless
experience exists to demonstrate the adequacy of the analysis, supported by
subcomponent tests or component tests to accepted lower load levels. The necessary
experience to validate an analysis should include previous component ultimate load
tests with similar designs, material systems, and load cases.
(i) The effects of repeated loading and environmental exposure, both of which
may result in material property degradation, should be addressed in the static strength
evaluation. This can be shown by analysis supported by test evidence, by tests at the
coupon, element or subcomponent levels, or alternatively by existing data. Earlier
discussions in this AC address the effects of environment on material properties (see
paragraph f.(2)) and protection of structure (see paragraph f.(3)). Static strength tests
Page C - 100