FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page Apdx B-15

PDF page 1189 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 1189
AC 27-1B · Apdx B-15Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

2/4/2016                                                  AC 27-1B, Chg 7


                      (3) Navigation System - one navigation system, including necessary sensor inputs
such as directional gyros.

                      (4) Transponder.

                      (5) ICS System - required for two pilot approval.

                      (6) Instrument Lights (or equivalent).

                (B) Avionic and instrument systems that should remain operational, for IFR approved
rotorcraft, after total failure of the electrical generating system. The rotorcraft must be capable of flight for
a minimum of 30 minutes. The suggested minimum equipment is as follows:

                      (1) Magnetic Compass.

                      (2) Airspeed-Altitude Attitude Presentation.

                      (3) Communications One VHF System.

                      (4) Instrument Lights (or equivalent).

                      (5) ICS System-For Two Pilot Approval.

                     (iii) Directional Instruments. A magnetic, gyro stabilized direction indicator is specified
because navigation in instrument flight must be precise. In rotorcraft, the nonstabilized magnetic indicator
is subject to many errors, particularly in turbulence. Therefore, it is inappropriate as the primary source of
directional information, but it is adequate as an emergency source. A nonslaved directional gyro is also
inappropriate as the primary source of directional information because of drift and the requirement to set it
to some other precise reference.

                (A) As a minimum for single pilot IFR, a nonstabilized magnetic indicator (such as a
“whiskey compass”) and a magnetic gyroscopically stabilized direction indicator system (slaved) are
required.

                (B) The minimum for dual pilot certification includes the instruments required for single
pilot, and an additional independent gyroscopically stabilized directional indicator system (slaved or
unslaved).

        (14) IFR Electrical System.

                  (i) General.

                (A) The entire electrical system, both AC and DC portions, should be reviewed with IFR
operation in mind. This review is necessary since most of the rotorcraft presently certificated do not
include IFR operation as part of their certification. Many aspects of normal operation and results of failure
conditions may be entirely acceptable for VFR operation but unacceptable for IFR operation.

                (B) Provisions should be made for a capability to continue flight to destination and
alternate airports in the event of a single failure in the electrical system. Section 27.1351 of this AC
contains the definition of a “single failure.” The evaluation of the system under failure conditions should
consider not only the failure itself, but also the recommended cockpit procedure to respond to any failure.

                (C) The fault analyses of the electrical system and the results of the system testing to
validate that analysis serves as a good starting place for the electrical system review. Failure of each
generator, each battery, and each component, such as switches and relays, should be accounted for first
since failure of equipment and components are the most probable.


                                                                   Page Apdx B - 15

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →