FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

PDF page 1027

PDF page 1027 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 1027
AC 27-1B · 1027Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

2/4/2016                                                  AC 27-1B, Chg 7


                (C) Powerplant and required system information should be arranged in a manner that is
easily accessed and readable.

                (D) CAS messaging should be displayed with the ability to display all possible warnings
without overflow.

                (iv) Reversionary mode display format.

                (A) Format of the primary flight information should not change.

                (B) HSI presentation in a reversionary mode should provide the same usability and
function as the non-reversionary mode. Navigation information should still be available and as close to
the same format as non-reversionary mode as possible.

                (C) Presentation of primary powerplant information the pilot uses to set and monitor
power should be prominent and graphically displayed.

                (D) Presentation of powerplant information pilots use to assess the health and ability of
the powerplant to develop power can revert to numerical displays if needed. Display of these parameters
numerically should include secondary cueing for the pilot in the event a parameter exceeds a cautionary
or limit value. For example, the numerical digit or field should provide a visual cue regarding its status as
it would in a normal display (see § 27.1322).

    e. System Requirements.

         (1) All parameters in EDS displays are to be designed in accordance with the relevant TSOs.
TSOA does not mean that the function or hardware meets the airworthiness certification requirements for
the rotorcraft in which it is to be installed.

         (2) A safety assessment should be provided as part of finding compliance with § 27.1309. The
following sections of this AC contain guidance on safety assessments:

        •   Section 27.1309, paragraphs d. (Safety Assessment), f. (Software), and g. (Airborne
            Electronic Hardware (AEH)).
        •  MG 21 (FHA).

         (3) Special considerations when determining failure condition classifications. Consideration
should be given to the type of operation that the system is intended to support. For example, failure
condition classifications for IFR installations are generally higher than VFR. Information contained on a
PFD is usually more critical, in most cases, than information on a MFD.

                  (i) VFR.

                (A) In a rotorcraft certificated to operate only under VFR, misleading information will
typically have a higher hazard categorization than a loss of information. The design should provide
mitigation to both as much as feasible since VFR operations at night can occur in areas that do not
provide pilots with good visual cues regarding the horizon or ground features.

                (B) PFD. Display of any non-required information such as synthetic vision should not
display misleading information. Loss of non-required information should not lead to confusion or affect
the ability of the pilot to access or assess required flight information.

                (C) Display of powerplant information. 14 CFR 27.1305 contains the required powerplant
instrument data to be displayed. Although each item is required, care should be taken with the loss of the
following, as applicable: low fuel warning, oil pressure warning for each gearbox, tachometer, and OEI
power levels.


                                                                   Page MG 19 - 25

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →