EASA Certification Specifications with AMC/GMFinal — current published edition checked

CS-29

Large Rotorcraft

Amendment 12 Source checked 2026-11-28

Scope, source and reading notes

Complete Easy Access Rules consolidation of CS-29 Amendment 12.

Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66

Source page 400 · PDF page 400

behaviour of the software on the end-user ground-based platform configuration(s). It is intended to be also used to ensure the compatibility and the correct behaviour in case new platforms (e.g. new OS, new processors, etc.) or new application software versions are released.

The end-to-end system integrity of the VHM information (including possible conversion means) should be ensured, e.g. by means of cyclic redundancy checks (CRC) protection of the data files or any other adequate means.

(j) Technical publications

Appropriate ICA are required by CS 29.1529 and Appendix A, which includes the VHM system itself and its applications. Thus, ICA and any other necessary supporting documentation should be available at entry into service and updated whenever necessary during the service life of the system.

(1) The ICA should typically include the following:

(i) Instructions to support the processing of each of the VHM system’s indications in accordance with (e)(4).

(ii) The recommended and MIDR in accordance with (e)(3).

(iii) The necessary procedures to ensure that sufficient complete data sets are available to allow for full diagnostics evaluation at the MIDR. In addition, the following details should be specified:

(A) The recommended and the minimum frequency of VHM data acquisition in accordance with (e)(1), as well as the necessary procedures to ensure that at least one complete data set is recorded within the required frequency.

(B) Means and procedures for data transfer, processing, networking and data integrity assurance.

(C) Methods to ensure the reliability of this process.

(D) The expected time required for upload/download and retrieval of data/health report.

(E) Facilities for storage of all data downloaded from the VHM systems and which permit timely access to the data.

(iv) The procedures to ensure that any alert is acted upon at an interval no greater than the MIDR.

(v) Provisions to support the mitigation of potential misleading information, missing or failed acquisition, and conflicting data from redundant sensors.

(vi) Effective scheduled maintenance to be carried out on the VHM system itself, when applicable, including inspections to confirm sensor performance and system functionality.

(vii) Troubleshooting and maintenance instructions to restore the VHM system functionality from any system failure.

(viii) Supporting information for all maintenance required on the VHM system, including

illustrated parts catalogue/illustrated parts breakdown and wiring diagrams.

(ix) Instructions to calibrate the system and verify that the computed indicators are representative of the condition of the monitored components.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 29-2C

Related technical context

Engineering context
Evidence and scope

CS-29 and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.