EASA Certification Specifications with AMC/GMFinal — current published edition checked

CS-29

Large Rotorcraft

Amendment 12 Source checked 2026-11-28

Scope, source and reading notes

Complete Easy Access Rules consolidation of CS-29 Amendment 12.

Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66

Source page 331 · PDF page 331

The applicant should use the outcome of the preliminary design assessment to determine the need for testing of each relevant area of the rotor drive system transmissions and gearboxes. If the applicant can justify that a location or area provides a conservative result, compared to other locations, the number of areas to be tested could be optimised. The preliminary design assessment should also determine those areas for which sufficient information is available from representative tests and in-service experience from previous designs.

Based on the conclusions of the preliminary design assessment, the applicant should determine the effectiveness of a chip detection system through a combination of the following two elements:

(1) a full-scale certification test of the transmission or gearbox by artificially introducing ferromagnetic particles.

The applicant should run this test in a series of phases, with measured amounts of ferromagnetic particles. The applicant should establish the quantity of ferromagnetic particles and the time needed to generate the caution/warning signal specified by CS 29.1305(a)(23) for each relevant area of the transmission or gearbox. The applicant should use this compliance method for those areas of transmissions or gearboxes whose effectiveness cannot be confidently established by a detailed design assessment as described in point (2).

In addition, the applicant should:

— perform the full-scale certification test in a fully representative gearbox, including its lubrication system. For gearboxes with pressurised lubrication, the applicant may replace some external elements of the lubrication system by test equipment, which can be justified to have no impact on the results.

— perform the full-scale certification test at a fixed attitude, rotational speed, and lubricating-oil temperature, corresponding to those at which the gearbox is expected to operate the most. The torque that is transmitted by the gearbox is considered irrelevant for this test.

— introduce the measured amount of ferromagnetic particles while the gearbox is rotating in stabilised conditions, wherever possible. Each introduction of particles should be performed in a way that represents as closely as possible the expected behaviour of particles that are produced by damage or wear.

— test each area that is identified for testing in a dedicated test phase, unless the applicant can justify that testing more than one area at the same time will still produce representative results for each area; and

— have a test procedure that ensures no contamination between the test phases. This often requires disassembling and thoroughly cleaning the gearbox being tested after each test phase.

(2) Detailed design assessment, using test data to support the performance of the relevant chip detectors in their local environments.

The applicant should use this assessment to demonstrate that the design provisions are adequate to ensure that the ferromagnetic particles that are released due to damage or excessive wear in the relevant locations will reach at least one chip detector. Sufficient test data to support the performance of the relevant chip detectors in representative environments should be available to demonstrate that the caution/warning signal that is specified in CS 29.1305(a)(23) is generated. When assessing the available test data, the

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 29-2C

Related technical context

Engineering context
Evidence and scope

CS-29 and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.