EASA Certification Specifications with AMC/GMFinal — current published edition checked

CS-29

Large Rotorcraft

Amendment 12 Source checked 2026-11-28

Scope, source and reading notes

Complete Easy Access Rules consolidation of CS-29 Amendment 12.

Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66

Source page 316 · PDF page 316

(10) An oil temperature warning device to indicate unsafe oil temperatures in each main rotor

drive gearbox, including gearboxes necessary for rotor phasing;

(11) A means to indicate the gas temperature for each turbine engine;

(12) A means to indicate the gas producer speed for each turbine engine;

(13) A tachometer for each engine that, if combined with the applicable instrument required

by sub-paragraph (a)(14), indicates rotor rpm during autorotation;

(14) At least one tachometer to indicate, as applicable:

(i) The rpm of the single main rotor;

(ii) The common rpm of any main rotors whose speeds cannot vary appreciably with respect to each other; and

(iii) The rpm of each main rotor whose speed can vary appreciably with respect to that of another main rotor;

(15) A free power turbine tachometer for each turbine engine;

(16) A means, for each turbine engine, to indicate power for that engine;

(17) For each turbine engine, an indicator to indicate the functioning of the power plant ice

protection system;

(18) An indicator for the fuel filter required by CS 29.997 to indicate the occurrence of

contamination of the filter to the degree established in compliance with CS 29.955;

(19) For each turbine engine, a warning means for the oil strainer or filter required by

CS 29.1019, if it has no bypass, to warn the pilot of the occurrence of contamination of the strainer or filter before it reaches the capacity established in accordance with CS 29.1019(a)(2);

(20) An indicator to indicate the functioning of any selectable or controllable heater used to

prevent ice clogging of fuel system components;

(21) An individual fuel pressure indicator for each engine, unless the fuel system which

supplies that engine does not employ any pumps, filters, or other components subject to degradation or failure which may adversely affect fuel pressure at the engine;

(22) A means to indicate to the flight crew the failure of any fuel pump installed to show

compliance with CS 29.955;

(23) Warning or caution devices to signal to the flight crew when ferromagnetic particles are

detected by the chip detection system required by CS 29.1337(e); and

(24) For auxiliary power units, an individual indicator, warning or caution device, or other

means to advise the flight crew that limits are being exceeded, if exceeding these limits can be hazardous, for:

(i) Gas temperature;

(ii) Oil pressure; and

(iii) Rotor speed.

(25) For rotorcraft for which a 30-second/2-minute OEI power rating is requested, a means

must be provided to alert the pilot when the engine is at the 30-second and 2-minute OEI power levels, when the event begins, and when the time interval expires.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 29-2C

Related technical context

Engineering context
Evidence and scope

CS-29 and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.