CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
an extremely remote lubrication failure. If compliance with CS 29.927(c) is reliant on the functioning of an auxiliary lubrication system, then:
(1) for the unlikely event of a combined failure of both the normal-use lubrication system and the auxiliary lubrication system, the applicant should perform additional loss of lubrication tests simulating this condition. The aim is to substantiate additional RFM emergency procedures for this combined failure to ensure the capability of the drive system to sustain a minimum duration of safe operation. These procedures should instruct the flight crew to ‘LAND IMMEDIATELY’ unless the additional tests performed representing this failure mode demonstrate that an increased duration is justified; and
(2) a means of verifying that the auxiliary lubrication system is functioning properly should be provided during normal operation of the rotorcraft on either a periodic, pre-flight or continual basis. Following a failure of the normal-use lubrication system and activation of an auxiliary lubrication system, the flight crew should be alerted in the event of any system malfunction.
(h) Independence of the auxiliary lubrication system.
(1) In order to ensure that the auxiliary lubrication system is sufficiently independent:
(i) a failure of any pressurised portion of the normal-use lubrication system should not result in a subsequent failure of the auxiliary lubrication system;
(ii) common failure modes shown to defeat both the normal-use and the auxiliary lubrication systems should be shown to be extremely remote lubrication failures, unless it is demonstrated by testing conducted to comply with CS 29.927(c) that the failure mode does not compromise the Maximum period of operation following loss of lubrication; and
(iii) control systems, logic and health-reporting systems should not be shared; consideration should be given to the design process to ensure appropriate segregation of the control and warning systems in the system architecture.
(2) Methods which should be used to demonstrate that failure modes of common areas are extremely remote include:
(i) field experience of the exact design with an exact application;
(ii) field experience with a similar design/application with supporting test data to allow a comparison;
(iii) demonstration by test of extremely low leakage rates;
(iv) redundancy of design;
(v) structural substantiation with a high safety margin for elements of the lubrication systems assessed against CS 29.571; and
(vi) assessment of the potential dormant failure modes of the auxiliary lubrication system, and in order to minimise the risk of dormant failures, determination of the health of the auxiliary lubrication system prior to each flight.
[Amdt No: 29/5] [Amdt No: 29/10] [Amdt No: 29/11]
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source