FAA Advisory circularActive — selected source checked

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

27-1B · Changes 1–9 incorporated Source checked 2026-11-28

Scope, source and reading notes

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

Aerospace Consulting reference note: Complete normal-category rotorcraft guidance, including system safety, equipment, flight guidance and IFR certification.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

Source page 662 · PDF page 662

with the loss of function. Installation design features to mitigate explosive increases in temperature or pressure may be required if energy storage system DALs are not suitable for the inherent hazard.

(E) Fluids or gases that may escape from an energy storage system or its installation may not damage surrounding structure or any adjacent systems, equipment, or electrical wiring of the rotorcraft (see § 27.1353(c)). Installation design data should include features to contain, vent, or drain these fluids or gases away from the rotorcraft. Flight tests may be required to evaluate the effectiveness of venting or draining throughout the normal operating envelope.

(F) Explosive or toxic gases that may be emitted by an energy storage system must not accumulate in hazardous quantities within the rotorcraft (see § 27.1353(b)). Installation design data should include features to contain or vent these gases away from the rotorcraft. Flight tests may be required to evaluate the effectiveness of venting or draining throughout the normal operating envelope.

(G) The energy storage system and its installation must prevent any hazardous effects on the rotorcraft structure or other installed systems caused by the maximum amount of heat generated during normal operation or by a failure of any part of the energy storage system or its installation (see § 27.1353(d)). Shielding, cooling, or venting provisions may be required to ensure that temperatures do not exceed allowed temperatures of any adjacent equipment, electrical wiring, hydraulic lines, or structure.

(H) Energy storage system temperatures and pressures must be maintained within a safe operating range during all foreseeable charging and discharging conditions, and during any failure of the control or monitoring functions (see § 27.1353(d)). Energy storage system installation design features must mitigate all hazards associated with monitoring and control failures (see § 27.1353(e)). The monitoring and control function implemented in hardware or software should have a DAL commensurate with the hazard associated with the loss of function.

(I) The instructions for continued airworthiness (ICA) must include maintenance requirements to ensure that required energy storage system maintenance functions are performed at appropriate intervals specified for each energy storage system component, to meet the requirements in Appendix A to Part 27. This is necessary to ensure system performance will not degrade below specified energy levels sufficient to power Rotorcraft systems for intended applications. Similarly, the ICA must also include procedures for the maintenance of energy storage system components in spares storage to prevent the replacement of components with stored components that have experienced degraded functional capability or other damage due to prolonged storage. Replacement energy storage system components must be of the same manufacturer and part number as initially approved, unless additional installation approval is obtained (see § 21.9(a)). Precautions should be included in the ICA maintenance instructions to prevent mishandling of the energy storage system components that could result in unintentional impact damage caused by dropping or other destructive means that could result in personal injury or property damage.

View figures, tables and original page layoutOriginal source page Source page 662 · PDF page 662 of AC 27-1B

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 29-2C

Related technical context

Engineering context
Evidence and scope

AC 27-1B and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source
CS-27

Related technical context

Engineering context
Evidence and scope

CS-27 and AC 27-1B — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.