FAA Advisory circularActive — selected source checked

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

27-1B · Changes 1–9 incorporated Source checked 2026-11-28

Scope, source and reading notes

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

Aerospace Consulting reference note: Complete normal-category rotorcraft guidance, including system safety, equipment, flight guidance and IFR certification.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

Source page 661 · PDF page 661

(A) The energy storage system capacity must be sufficient to supply the required current at a voltage level that allows proper operation of the equipment or functions dependent on the energy storage system. This capacity must be shown to be sufficient at the proper voltage levels for all operational and environmental conditions, as required by § 27.1351(a)(1). Any energy storage system required for continued safe flight and landing of the rotorcraft must have monitoring features and the means to indicate to the pilot the status of all critical system parameters (see § 27.1353(e)). Accordingly, warning, caution, or advisory indication must be provided appropriate to any hazard condition. Section 91.167 requires Rotorcrafts approved for IFR operations have sufficient back-up power to operate a minimum set of required equipment for a time long enough to find a suitable place to land and effect a safe landing if primary power generation fails. The minimum time for IFR is 30 minutes. Additionally, for rotorcraft that employ electrical power for starting, to meet the requirements in § 27.1351, the energy storage system must have sufficient capacity to provide adequate engine starting on the ground, and also to provide power for the air start function, when required. The power requirement for air start could have high-level safety considerations depending on the rotorcraft power distribution system and the number of engines.

(B) The energy storage system must be qualified for the specific location and rotorcraft environment. Acceptable environmental test procedures may be found in RTCA DO-160, which provides test procedures to meet a wide range of environmental conditions that may exist on a wide variety of aircraft. Environmental tests should meet or exceed the expected installation environment. In addition to the environmental qualification, the equipment and installation design should consider the risk of explosion presented by the production of gases that occur during normal operation or as a result of any failed condition. An explosive resistant case or safe venting may be an acceptable way of showing compliance if it is shown that structure and essential systems do not suffer hazardous effects that jeopardize continued safe flight and landing.

(C) Energy storage systems shall have protective features to prevent unsafe conditions during operation. The protective features shall automatically control all critical operational parameters of the system in order to prevent any unsafe condition. The term “automatically” is intended to preclude pilot action as a mitigating feature and is not intended to require a specific mitigating design feature. Development assurance levels (DAL) for hardware and software that implement monitoring and control functions should be commensurate with the effect associated with system failure. An acceptable certification process for airborne software is found in AC 20-115 and, for complex hardware, in AC 20-152.

(D) The occurrence of self-sustaining, uncontrolled increases in temperature or pressure must be prevented for normal energy storage system operation or as a result of a failure of any part of the system installation (see § 27.1353(d)). System architecture should ensure that a component failure does not propagate to adjacent components. A safe design may require a compartmentalized structure to prevent cascading failures. Any required monitoring and control functions implemented in hardware or software should have a DAL commensurate with the hazard associated

View figures, tables and original page layoutOriginal source page Source page 661 · PDF page 661 of AC 27-1B

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 29-2C

Related technical context

Engineering context
Evidence and scope

AC 27-1B and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source
CS-27

Related technical context

Engineering context
Evidence and scope

CS-27 and AC 27-1B — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.