FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

PDF page 881

PDF page 881 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 881
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

4/25/06                                       AC 27-1B, Chg 2


               (3) Arrested Growth Evaluation. This method is applicable when the flaw
grows, but the growth is mechanically arrested or terminated before becoming critical
(residual static strength reduced to limit load), as illustrated in Figure AC 27 MG 8-4.
Arrested Growth may occur due to design features such as a geometry change,
reinforcement, thickness change, or a structural joint. This approach is appropriate for
inspectable arrested growth damage. Structural details, elements, and sub-components
of critical structural areas, components or full-scale structures, should be tested under
repeated loads for validating an arrested growth approach to the flaw tolerance
requirements. The number of cycles applied to validate an arrested growth concept
should be statistically significant, and may be determined by load and/or life
considerations. Residual strength testing or evaluation should be performed after
repeated load cycling and demonstrate that the residual strength of the structure is
equal to or greater than limit load considered as ultimate. Moreover, it should be shown
that stiffness properties have not changed beyond acceptable levels. Inspection
intervals should be established, considering the residual strength capability associated
with the arrested growth damage. The intent of this is to ensure that structure is not
exposed to an excessive period of time with static margins less than ultimate, providing
a lower safety level than in the typical slow growth situation, as illustrated by Figure
AC 27 MG 8-3. For any damage size that reduces load capability below ultimate, the
component is either repaired to restore ultimate load capability or replaced.

The lower the residual strength caused by an arrested growth event, the shorter the
inspection interval should be. Considerations of both inspectability and impact surveys
(including probability of occurrence) for specific structure may be used to isolate the
most critical threats to consider in setting a maintenance inspection interval. Knowledge
of the residual strength for a given critical damage is also needed for such an
evaluation.  If it is known that the design is capable of handling large and clearly
detectable damage, while maintaining a residual strength well above limit load, a less
rigorous engineering approach may be applied in establishing the inspection interval.

             (C) Safe-Life Evaluation. This method demonstrates that the structure, in
an as-manufactured condition, is able to withstand repeated loads of variable magnitude
without detectable cracks, disbonds, or delaminations for the life of the rotorcraft or
within a specified retirement time.  It is available for use only when both the Fail-Safe
and Flaw Tolerant Safe-Life methods have been shown to be impractical due to
considerations of geometry, inspectability, or good design practice. Further guidance
for Safe-Life substantiation is provided in AC 27-1B, Chg 1, MG-11, “Fatigue Evaluation
of Rotorcraft Structure”. The fatigue test articles should be fabricated and assembled in
accordance with production specifications and processes so that they are
representative of production structure including defects consistent with the limits
established by manufacturing acceptance criteria.

             (D) Combination of Safe Life and Fail Safe Evaluations. Generally it may
be appropriate to establish both a retirement time and an inspection program for a given
structure.



                                                       Page MG 8 - 25

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.