This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page G-22

PDF page 735 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 735
AC 27-1B · G-22Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

AC 27-1B, Chg 4                                                     3/31/2014

         (1) Limits. Each maximum allowable limit substantiated for safe operation must
be marked with a red line. This marking should be a red radial line for circular gauges.
If there is a minimum allowable limit for safe operation, this value should also be marked
with a red radial line. The use of multiple red radial lines should be avoided except
where their use is readily apparent to the flight crewmember. Normally, no more than
one maximum and one minimum red radial line should be incorporated on any one
instrument to minimize confusion and avoid potential flightcrew errors; however, use of
multiple red radial lines may be permitted if such markings can be presented in an
acceptable manner.

         (2) Normal Operating Range. Each normal operating range should be marked
with a green arc or green line which does not extend beyond the maximum and
minimum values for continuous safe operation. Discontinuities in width have been used
when normal ranges vary with other parameters. Integrating instruments in place of
these markings should be encouraged although there may be no regulatory requirement
for them. An equivalent safety finding is required for electronic displays if the applicant
decides not to use green to mark normal operating ranges.

         (3) Cautionary Ranges. Time limited ranges, precautionary ranges, or ranges
for which special operating procedures are required should be marked with a yellow arc
or yellow line.  If a yellow range is used to indicate a special operating procedure,
information describing the special procedure should be included in the RFM.

         (4) OEI Markings. OEI ratings represent a special challenge for retaining
simplicity and clarity in powerplant instrument markings. OEI ratings are eligible to be
used only during an extremely small portion of total flight time; therefore, they should
not dominate the presentation or obscure other markings. They are needed only for
reference. Indices for 2 ½-minute and 30-minute power may be marked above the
takeoff power redline on engine power instruments. OEI reference markings should be
clearly distinct from the normal all-engines-operating markings. One acceptable means
of marking OEI limits has been narrow dashed radials with yellow for 30-minute and red
for 2 ½-minute limits. OEI markings should be consistent between gauges. For
example, a 30-minute marking on an N1 or torque gauge should be similar in
appearance to the 30-minute marking on the engine temperature gauge.

         (5) Red Arcs or Ranges. Sections 27.1549(d) and 27.1553 allow the use of red
arcs. Experience has proven that when red arcs are used to indicate maximum or
minimum values, the meaning of a red line loses its significance. Therefore, the use of
red ranges or arcs to indicate limit values should be discouraged. Red is conventionally
used to represent a limit (maximum or minimum) for which an aircraft or component has
been substantiated. A “range” of limits for a given parameter is not consistent with the
definition of the terms “limit,” “minimum,” or “maximum.” In addition, a red arc tends to
imply that more than one value is limiting, that a scale is provided to show operation
within a range of values, and that an absolute limit may not exist until the extreme of a
red range is attained. These implications must be avoided wherever possible by



Page G - 22

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →