FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page F-61

PDF page 657 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 657
AC 27-1B · F-61Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

2/12/03                                       AC 27-1B, Chg 1

operate properly within all specified limits. Operational specified limits may be set by
battery charging in-rush currents or possible fault currents.

              (B) A battery charge control system may be used that automatically
controls the battery charge to prevent battery overheating. Unless otherwise specified
by the battery manufacturer, temperatures above 140° F are considered overheat for
NI-CAD batteries. The system is acceptable if the charge rate is automatically adjusted
by controlling the charging current as a function of battery temperature, and in an
over-temperature condition, the charge current is automatically reduced to a safe value.
Zero to 10 amperes has been considered safe for batteries rated at less than
34 amp-hours, and zero to 15 amperes has been considered safe for batteries rated at
34 amp-hours or more. The actual number chosen should be substantiated. Means
and/or procedures should be provided for the crew to monitor the charger performance
or the battery condition.  If there is an automatic disconnect of the charger from the
batteries and associated bus on an over-temperature condition, provisions should be
provided in the cockpit to warn of a disconnect.

             (C)  If a temperature monitoring system is used, the temperature sensor
should be located in a position that will most accurately reflect the internal battery
temperature without causing adverse effects to the sensor. The location normally used
is near the center of the battery.  If the sensor is placed between two cells, the
indication should be very close to the actual temperature within the cell.  If the sensor is
placed in a cell strap, there will normally be a period of time just after a heavy current
drain (e.g. engine start) when the sensor shows a temperature that is hotter than the
actual cell temperature.

             (D) Battery failure sensing and warning systems have also been used to
show compliance with this rule.

         (3) Battery replacement with any battery other than the one that was installed
and accepted as part of the original type design must consider several aspects of
battery design and installation to assure that the type design is not negatively impacted.

                  (i)   The replacement battery should provide at least the minimum usable
capacity as required by the current load analysis. This requirement of minimum usable
capacity should be valid over the entire range of environmental conditions. Different
types of batteries have different inherent characteristics. Nickel cadmium batteries have
a voltage discharge curve that allows most of the amp-hour capacity to be usable from a
delivered voltage standpoint, where only about 66% of the amp-hour capacity for lead
acid batteries is usable due to the delivered voltage becoming too low to use. If a
replacement battery has a similar discharge rate, and the capacity is similar throughout
the original battery’s environmental range, then no further testing should be needed.

                   (ii)   Replacement batteries must be compatible with type design
requirements of the helicopter (reference paragraph b(2)(i)(A) above). For IFR and
CAT A certified helicopters that depend on fault clearing features, an analysis may be


                                                          Page F - 61

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →