FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

PDF page 651

PDF page 651 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 651
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

9/30/2008                                       AC 27-1B, Chg 3

documented sufficiently to maintain configuration control for manufacturing and to
assure that the electromagnetic characteristics remain the same as the certification
sample.

         (3) Generating System. When electrical power is needed for essential
equipment, this paragraph requires at least one generator with adequate capacity for
safe operation. Complete electrical failures have been caused by loss of voltage control
in the voltage regulator. Overvoltage conditions can destroy electronic equipment. An
acceptable method of overvoltage protection is the use of a separate overvoltage
sensing relay to trip the generator off the line when overvoltage is detected. Another
acceptable method is use of a voltage regulator with built-in overvoltage protection.

         (4) Generator Ratings: Generator ratings are often the result of installation
temperature limitations. The determination of these limitations, if any, is by testing the
actual installation. The procedures for performing generator cooling tests are as
follows:

                  (i)   Test Requirements.

              (A) General. The applicant should contact the generator (alternator)
manufacturer and obtain the maximum limits (continuous, 2 minute intermittent and 5
second transient maximum limits) for the unit to be tested. This will normally be in
terms of temperatures at various locations within the unit (stator, bearings, diodes, heat
sinks, brushes, etc.) or in terms of pressure drop across the generator. The
manufacturer should either supply an instrumented unit or give complete details for
instrumenting the test unit.

              (B) Instrumentation.

               (1) Load Bank. A load bank will usually be necessary to load the test unit
to the amperage limit for which approval is requested.

               (2) Ammeter. An ammeter should be provided with sufficient resolution to
assure the amperage load is being maintained at the desired level.

               (3) Temperature/Pressure Readouts. Readouts which are compatible
with the temperature or pressure sensors installed in the test unit should be provided.

               (4) Calibration Records. Calibration records should be available for all
instrumentation.

               (5) Recordings. Permanent recordings should be provided for time,
temperatures, current, and/or pressure. The recording device should have provisions
for placing event marks on the recording medium.




                                                        Page F – 55.2

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →