FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page D-8

PDF page 277 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 277
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

AC 27-1B, Chg 4                                                     3/31/2014


AC 27.610.    § 27.610 (Amendment 27-46) LIGHTNING AND STATIC
             ELECTRICITY PROTECTION.

Background. During the initial development and promulgation of airworthiness
standards, rotorcraft operated primarily in a VFR and non-icing environment. A prudent
pilot avoided thunderstorms where the possibility of encountering severe weather and a
lightning strike was much greater. Now, many rotorcraft are authorized to fly under IFR
and into known icing conditions. Because many rotorcraft now use the same advanced
technologies in structures and systems as fixed-wing aircraft, a specific rule on lightning
protection of rotorcraft was adopted in Amendment 27-21. Amendment 27-37 revised
the title of § 27.610 to include protection from static electricity, and a new § 27.610(d)
was added specifying requirements for electrical bonding and protection against
lightning and static electricity. Amendment 27-46 removed the system lightning
protection requirements for electrical and electronic equipment in § 27.610(d)(4)
because those requirements were implemented in the new § 27.1316.

     b. Explanation.

         (1) The regulation requires protection of rotorcraft from the catastrophic effects
of lightning. This means that lightning must not prevent the continued safe operation of
the rotorcraft.

(2) Rotorcraft structural components, propulsion system, gearboxes, and mechanical
and hydraulic control systems should be designed to ensure lightning will not prevent
continued safe flight and landing of the rotorcraft (i.e., damage due to lightning currents
that flow through any of these components must not result in catastrophic failure).

      c. Procedures.

Certification Plan. A formal written certification plan is an acceptable means to ensure
demonstration of regulatory compliance. This plan is also useful to identify and define
an acceptable resolution to the critical issues early in the certification process. These
are the usual steps to follow when utilizing a certification plan:

                  (i) Prepare a certification plan that describes the analytical procedures and
qualification tests to be utilized to demonstrate lightning and static electricity protection
effectiveness. Test proposals should describe the rotorcraft and system to be utilized,
test drawing(s) as required, the method of installation that simulates the production
installation, the lightning zone(s) applicable, the lightning simulation method(s), test
voltage or current waveforms to be used, diagnostic methods, and the appropriate
schedules and location(s) of proposed test(s).

                   (ii) Obtain FAA/AUTHORITY concurrence that the certification plan is
adequate.



Page D - 8

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →