FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page C-113

PDF page 263 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 263
AC 27-1B · C-113Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

12/1/2011                                       AC 27-1B, Chg 4


critical (residual static strength reduced to limit load), as illustrated in Figure
AC 27.573-4. Arrested Growth may occur due to design features such as a geometry
change, reinforcement, thickness change, or a structural joint. This approach is
appropriate for inspectable arrested growth damage. Structural details, elements, and
sub-components of critical structural areas, or full-scale structures, should be tested
under repeated loads for validating an arrested growth approach to the flaw tolerance
requirements. The number of cycles applied to validate an arrested growth concept
should be statistically significant, and may be determined by load or life considerations,
or both. Residual strength testing or evaluation should be performed after repeated
load cycling and a demonstration that the residual strength of the structure is equal to or
greater than limit load considered as ultimate. Moreover, it should be shown that
stiffness properties have not changed beyond acceptable levels. Inspection intervals
should be established, considering the residual strength capability associated with the
arrested growth damage. The intent of this is to assure that structure is not exposed to
an excessive period of time with static margins less than ultimate, providing a lower
safety level than in the typical slow growth situation, as illustrated by Figure
AC 27.573-3. For any damage size that reduces the load capability below ultimate, the
component is either repaired to restore ultimate load capability or replaced.

The lower the residual strength of a structure after an arrested growth event, the shorter
the inspection interval should be. Considerations of both inspectability and impact
surveys (including probability of occurrence) for specific structure may be used to
isolate the most critical threats to consider in setting a maintenance inspection interval.
Knowledge of the residual strength for a given critical damage is also needed for such
an evaluation.  If it is known that the design is capable of handling large and clearly
detectable damage, while maintaining a residual strength well above limit load, a less
rigorous engineering approach may be applied in establishing the inspection interval.

          (C) Combination of Damage Tolerant Safe Life and Fail Safe Evaluations.
Generally, it may be appropriate to establish both a replacement time and an inspection
program for a given structure as calculated by the Damage Tolerant Safe Life and Fail
Safe Evaluations.

          (D) Other Procedures. Other procedures are allowed according to
§ 27.573(d). Such alternative procedures must still provide the same degree of damage
tolerance to the same identified threats as the replacement time or inspection interval
methods.

One possible alternate approach is the use of indirect damage detection methods
instead of the specific mandated inspection procedures that are determined in the Fail
Safe Evaluations of f.(6)(iii)(B). These indirect detection methods should be
documented and shown to have the same degree of reliability, repeatability, and margin
provided by a conventional inspection approach. These methods could include: (1)
establishing measurable vibration or blade out-of-track conditions and limits, (2) defining
indirect inspections, which would detect damage, and (3) in-flight detecting of damage
by means of monitoring and warning devices.


                                                         Page C - 113

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →