AC 27-1B
Certification of Normal Category Rotorcraft — Changes 1–9
27-1B · Changes 1–9 incorporated Source checked 2026-11-28
Scope, source and reading notes
This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.
Aerospace Consulting reference note: Complete normal-category rotorcraft guidance, including system safety, equipment, flight guidance and IFR certification.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b
(12) Cross Coupling. IFR handling qualities are enhanced by providing low levels of coupling between axes. During the flight evaluation, pilots should be alert for strong cross coupling tendencies between yaw and pitch, heave (collective) and pitch, heave and roll, or roll and pitch. Any strong coupling effects between these motions may produce unacceptable handling qualities for IFR flight. The rotorcraft should be able to make a smooth transition from any flight condition. As an example, large rolling or pitching moments with collective application would represent questionable handling characteristics for the IFR missed approach condition.
(13) Electrical, Avionics, and Instruments. Some aircraft have been certificated with different equipment from that suggested in this subparagraph because the certification criteria for IFR have evolved in several stages. The following guidance refers to the latest certification requirements:
(i) Additional Avionics and Instruments. The avionics and instruments required for certification for operations under IFR beyond those required by § 27.1303 should meet the installation requirements of § 29.1303 as follows:
(A) Attitude Indicator. Power for operation and lighting must be independent from the rotorcraft electrical generating or starting system, and the instrument markings must meet the minimum usability requirements of §29.1303(g)(1). Section 29.1303 of this AC provides additional guidance on marking requirements for attitude indicators. Operation must be maintained for a minimum of 30 minutes after total aircraft electrical power generating system failure. For dual pilot configurations, one pilot’s primary indicator may be designated for this purpose, provided standby batteries are provided.
(B) Alternate Static Source. An alternate static source with a means of selecting this source must be provided for single pilot configurations.
(C) Direction Indication. Gyro Stabilized. Magnetic in place of non-magnetic required by § 27.1303(h).
(D) Navigational Systems. Navigational systems required by the applicable operational rules must be provided.
(E) Communication Systems. Communication systems required by the applicable operational rules must be provided.
(F) Other electrical and electronic equipment. Other electrical and electronic equipment required by the applicable operational rules must be provided.
(ii) Electrical Power Availability for Avionic and Instrument Systems. Minimum avionic and instrument systems should remain operative after electrical power failures in relation to IFR operation. The lists that follow suggest the minimum Avionic and Instrument Systems that should remain operational after a single failure of the generating system and after failure of all but the emergency power source. These lists do not address the basic equipment required for non-IFR related operation. These basic equipment requirements are addressed by the appropriate paragraph of this guidance.
(A) Avionic and instrument systems that should remain operational, for IFR approved rotorcraft, after a single failure of the electrical generating system. The rotorcraft must be capable of IFR flight to destination and alternate airports. The suggested minimum avionic and instrument systems are as follows:
(1) Flight Instruments - the same as § 27.1303 requirements, except as defined by paragraphs b.(13)(i)(A) and (C).
(2) Communications - one VHF radio.
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 27-1B and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting sourceRelated technical context
Engineering contextEvidence and scope
CS-27 and AC 27-1B — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source