Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

PDF page 879

PDF page 879 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 879
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

4/25/06                                       AC 27-1B, Chg 2


              (B) Fail-Safe (Residual Strength after Flaw Growth) Evaluation. This
method demonstrates that the structure following a partial failure still has a sufficient
residual strength capability within a specified inspection interval or the established
retirement life of the component.  If a retirement life is established, an ultimate design
load capability is generally required while, if an inspection interval is determined, a limit
load capability is the minimum acceptable residual strength capability that needs to be
demonstrated. Full-scale, component, or sub-component testing should be
accomplished using one or more specimens subjected to constant amplitude or
spectrum loading applied in a manner representative of flight load conditions. The test
loads should be increased by factors that account for environment and fatigue strength
scatter. The results of the testing can be used to manage the structure in one of the
three methods described below or a combination thereof.

               (1) Fail-Safe, No Growth Evaluation. This approach is appropriate for
inspectable in-service accidental damage. Structural details, elements, and sub­
components of critical structural areas, components, or full-scale structures, should be
tested under repeated loads for validating a no-growth approach to the flaw tolerance
requirements. The number of cycles applied to validate a no-growth concept should be
statistically significant, and may be determined by load or life considerations. Residual
strength testing or evaluation should be performed after repeated load cycling and
demonstrate that the residual strength of the structure is equal to or greater than limit
load considered as ultimate. Moreover, it should be shown that stiffness properties
have not changed beyond acceptable levels. Inspection intervals should be
established, considering the residual strength capability associated with the assumed
damage. The intent of this is to assure that structure is not exposed to an excessive
period of time with static margins less than ultimate, providing a lower safety level than
in the typical slow growth situation, as illustrated in the Figure AC 27 MG 8-3. Once the
damage is detected, the component is either repaired to restore ultimate load capability
or replaced.

                        Damage initiation  Residual strength
                               or occurrence
                                   ~
                                             Slow-growth approach *           ,   t
    Ultimate loads                                          I'-...
                                 No-growth approach **
      Limit loads

                                                      * Repair to Restore Ultimate St rength
                                                    ** No growth without repair is not acceptable
                                                                        Time--
               Figure AC 27 MG 8-3: Residual Strength vs. Time



                                                       Page MG 8 - 23

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →