FAA Advisory circularActive — selected source checked

AC 25.1309-1B

System Design and Analysis

25.1309-1B · 2024-08-30 Source checked 2026-11-28

Scope, source and reading notes

Guidance for showing compliance with §25.1309. Confirm the applicable amendment level and accepted means for the programme.

Aerospace Consulting reference note: A starting point for transport-airplane system-safety assessment and development-assurance connections.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 90e625593d472b74ec69fbcefe97649f97794410dbe844f7684b397121ac5a92

Source page 65 · PDF page 65

AC 25.1309-1B Appendix D

TABLE D-1. EXAMPLE OF CSL+1 IDENTIFICATION FOR § 25.1309(B)(5) COMPLIANCE

Section 25.1309(b)(5)(ii) and

Exposure

MCS No.

Combined Probability

Basic Event CSL+1? Failure

Rate

time Event Probability

(iii) Applicability and Compliance

1 1.0 x 10-9 A001

1 x 10-7 2.5 h 2.5 x 10-7 Not compliant with limit

L001 4 x 10-6 1000 h 4 x 10-3

Yes

latency criterion since L001 probability is more frequent than 1 x 10-3.

2 5.000x 10-10 A002

L003 1 x 106 10 h 1 x 10-5

Yes

2 x 10-5 2.5 h 5 x 10-5 Not compliant with residual risk criterion since A002 probability is more frequent than 1 x 10-5/FH

3 2.500 x 10-

A004

1 x 10-5 2.5 h 2.5x 10-5 Note: MCS no. #2 and #3 are

10

L003 1 x 10-6 10 h 1 x 10-5

Yes

grouped due to common L003. Although A004 probability is equal to 1 x 10-5/FH, the residual risk criterion is not met because the combined probability of A004 and A002 (2.5 x 10-5 + 5 x 10-5)/FH is more frequent than 1 x 10-5/FH.

4 2.500 x 10-

A004

1 x 10-5 2.5 h 2.5 x 10-5 Compliant with both limit

10

L005 1 x 106 10 h 1 x 10-5

Yes

latency and residual risk criteria. Note: MCS no. #3 and #4 are grouped due to common A004. Combined L003 and L005 ((1 x 10-5 + 1 x 10-5) is less than 1 x 10-3

5 1.250 x 10-

A002

10

A005 1 x 10-6 2.5 h 2.5 x 10-6

No

2 x 10-5 2.5 h 5 x 10-5 Section 25.1309(b)(5) does not apply since this dual failure combination does not contain any latent failure.

6.5 x 10-

6 1.625 x 10-

A003

2.5 h 1.625 x 10-6 Compliant with both limit

12

7

L004 1 x 10-7 10.0 h 1 x 10-6

Yes

latency and residual risk criteria. A003 = 1.625x10-6/FH is less than 1.0x10-5/FH L004=1x10-6 less than 1x10-3

7 1.000 x 10-

A002

10

No

2 x 10-5 2.5 h 5 x 10-5 Section 25.1309(b)(5) does not apply since this is a triple- failure combination. L001 4 x 10-6 1000 h 4 x 10-3

L002 5 x 10-6 100 h 5 x 10-4

MCS: Minimal Cut Set: the smallest set of events whose occurrence is sufficient to cause the Top event or failure condition. A: Active failure; L: Latent failure Flight time = 2.5 hour of flight P[LAT i] ~ FR * T

View figures, tables and original page layoutOriginal source page Source page 65 · PDF page 65 of AC 25.1309-1B

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

14 CFR 25.1309

Provides compliance guidance for

Source-backed
Evidence and scope

FAA AC 25.1309-1B Cover and §1.1, printed p1-1 / PDF p6; FAA AC 25.1309-1B Appendix A §A.5, printed pA-3 / PDF p53

Provides acceptable means for compliance with 14 CFR 25.1309. Connects the rule change to amendment25-152 and notes harmonisation of failure-condition/probability terms with AMC 25.1309; this is not whole-document equivalence.

Assess against the applicable project amendment; current source and certification basis are distinct.

Supporting source
ARP4754 document family

References latest version

Source-backed
Evidence and scope

FAA AC 25.1309-1B §1.4.5, printed pp1-7–1-8 / PDF pp12–13

Lists ARP4754 and ARP4761 without revision suffixes and explicitly instructs use of the latest referenced version. Preserve this revision policy rather than pinning the reference to legacy editions.

Do not display this as an explicit suffix-B citation; preserve family reference and latest-version instruction.

Supporting source
ARP4761 document family

References latest version

Source-backed
Evidence and scope

FAA AC 25.1309-1B §1.4.5, printed pp1-7–1-8 / PDF pp12–13

Lists ARP4754 and ARP4761 without revision suffixes and explicitly instructs use of the latest referenced version. Preserve this revision policy rather than pinning the reference to legacy editions.

Do not display this as an explicit suffix-A citation; preserve family reference and latest-version instruction.

Supporting source
AC 20-174

References development-assurance guidance

Source-backed
Evidence and scope

FAA AC 25.1309-1B §5.3.4, printed p5-4 / PDF p30

References AC 20-174 for aircraft/system assurance, AC 20-115D for software and AC 20-152A for hardware.

Read the cited document’s applicability and the project certification basis.

Supporting source
AMC 25.1309

Related EASA safety guidance

Engineering context
Evidence and scope

FAA AC 25.1309-1B Appendix A §A.5, printed pA-3 / PDF p53

Connects the rule change to amendment25-152 and notes harmonisation of failure-condition/probability terms with AMC 25.1309; this is not whole-document equivalence.

Harmonised terms do not establish whole-document equivalence.

Supporting source
AC 20-152A

References hardware guidance

Source-backed
Evidence and scope

AC 25.1309-1B §5.3.4.2, printed p5-4 / PDF p30

Identifies AC 20-152A as hardware development-assurance guidance.

Read the source scope and applicable project basis.

Supporting source
AC 23.1309-1E

Related technical context

Engineering context
Evidence and scope

AC 23.1309-1E and AC 25.1309-1B — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.