FAA Advisory circularActive

AC 20-136C

Aircraft Electrical and Electronic System Lightning Protection

20-136C Source checked 2026-11-28

Scope, source and reading notes

Aircraft electrical and electronic system lightning protection for applicable Part 23, 25, 27, and 29 certification requirements.

Aerospace Consulting reference note: Describes a means of demonstrating lightning-protection compliance for aircraft systems; revision C supersedes AC 20-136B.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: a97137a34f9094ac10e6fb7caba11688edf5ab0b866ddf3d5ffa40f00e327cdd

Source page 54 · PDF page 54

AC 20-136C Appendix C

Example C-8 LCL Comparison to Development Assurance Level (DAL) Function

Function System Channel

System Channel System Channel

Passive Back-up (high pressure switch + valve)

Active (pneumatic system controller #2)

Active (pneumatic system controller #1)

Control and protection of the aircraft pneumatic (bleed) system (top-level failure condition classification: catastrophic).

FDAL C

FDAL B

Functional DAL (FDAL) B

Applicable paragraph in § 25.1316 (a)(1) and (2) (a)(1) and (2) (b)

Discussion:

This is a generic example to show that the LCL of a given system may be different from the FDAL and item development assurance level (IDAL), as defined in SAE ARP4754A. Therefore, it is important to use the proper nomenclature and avoid using ARP4754A “DAL” or similar terms when referring to the LCL.

In this example, the pneumatic control system is composed of two main active controllers and a simpler passive back-up channel that can perform the function, preventing a catastrophic event should both controllers fail.

The FDAL for each channel or member (ARP4754A nomenclature) in this example was determined for a catastrophic top-level failure condition based on the “Option 2” column of Table 3 “DEVELOPMENT ASSURANCE LEVEL ASSIGNMENT TO MEMBERS OF A FUNCTIONAL FAILURE SET” in ARP4754A, which allows the combination of FDAL B+B+C for independent channels. In contrast, the respective LCLs would be A+A+B.

Considering that lightning can simultaneously affect all channels, the considerations used for FDAL assignment are not sufficient. Compliance with § 25.1316(a) is required for both active channels performing a function with a catastrophic top-level failure condition.

The FDAL for the passive back-up channel may be C in this example. However, for lightning, the applicable paragraph in § 25.1316 is (b) based on the aircraft safety assessment identifying a hazardous failure condition (LCL B).

View figures, tables and original page layoutOriginal source page Source page 54 · PDF page 54 of AC 20-136C

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-136A

Related technical context

Engineering context
Evidence and scope

AC 20-136C and AMC 20-136A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.