FAA Advisory circularActive

AC 20-136C

Aircraft Electrical and Electronic System Lightning Protection

20-136C Source checked 2026-11-28

Scope, source and reading notes

Aircraft electrical and electronic system lightning protection for applicable Part 23, 25, 27, and 29 certification requirements.

Aerospace Consulting reference note: Describes a means of demonstrating lightning-protection compliance for aircraft systems; revision C supersedes AC 20-136B.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: a97137a34f9094ac10e6fb7caba11688edf5ab0b866ddf3d5ffa40f00e327cdd

Source page 38 · PDF page 38

11.5.2 You should evaluate any equipment effects observed during the qualification tests to ensure these do not adversely affect the system’s continued performance. You should obtain the cognizant certification branch’s approval of your evaluation.

11.5.3 Multiple stroke and multiple burst testing is not required if an analysis shows that the equipment is not susceptible to upset, or that the equipment may be susceptible to upset, but a reset capability exists so the system recovers in a timely manner.

11.6 Step 6 – Verify System ETDLs Using Existing Equipment Data (Similarity).

11.6.1 You may verify ETDLs by similarity to previously certified systems without performing more tests. You may do this when:

• There are only minor differences between the previously certified system and installation, and the system and installation to be certified;

• There are no unresolved in-service system problems related to lightning strikes on the previously certified system; and

• The previously certified system ETDLs were verified by qualification tests.

11.6.2 The assessment should cover:

• Equipment interface circuits;

• Wire size, routing, arrangement (parallel or twisted wires), connector types, wire shields, and shield terminations;

• Lightning protection devices such as transient suppressors and lightning arrestors;

• Grounding and bonding; and

• Equipment software, firmware, and hardware.

11.6.3 If significant differences are found that will affect the systems and installations, you should perform more tests and analyses to resolve the open issues.

11.7 Step 7 – Verify Compliance with the Requirements. You should demonstrate that the LCL B and C systems meet their defined acceptance criteria during the qualification tests at the selected system ETDLs.

11.8 Step 8 – Take Corrective Measures. When your system fails to meet the certification requirements, you should decide on corrective actions. If you change or modify the system or installation, you may need to repeat equipment qualification testing. You should review these changes or modifications with the cognizant certification branch to determine if they are significant. If these changes or modifications are significant, update your lightning certification plan accordingly. The updated certification plan should be resubmitted to the certification branch for review.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-136A

Related technical context

Engineering context
Evidence and scope

AC 20-136C and AMC 20-136A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.