AC 20-136C
Aircraft Electrical and Electronic System Lightning Protection
20-136C Source checked 2026-11-28
Scope, source and reading notes
Aircraft electrical and electronic system lightning protection for applicable Part 23, 25, 27, and 29 certification requirements.
Aerospace Consulting reference note: Describes a means of demonstrating lightning-protection compliance for aircraft systems; revision C supersedes AC 20-136B.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: a97137a34f9094ac10e6fb7caba11688edf5ab0b866ddf3d5ffa40f00e327cdd
7.3.3.1.2 The lightning safety assessment should consider effects of lightning- related failures or malfunctions on systems with lower failure classification that may affect the function of LCL A systems. You should demonstrate that any system with wiring connections to an LCL A system will not adversely affect the functions with catastrophic failure conditions performed by the LCL A system when the aircraft is exposed to lightning. Redundancy alone cannot protect against lightning because the lightning- generated electromagnetic fields, conducted currents, and induced currents in the aircraft, can simultaneously induce transients in all electrical wiring on an aircraft.
7.3.3.2 LCL B or C Systems. You must demonstrate compliance with §§ 23.1306(b) (amendment 23- 61), 23.2515(b), 25.1316(b), 27.1316(b), or § 29.1316(b), for a system that performs a function whose failure would reduce the capability of the aircraft or the ability of the flightcrew to respond to an adverse operating condition. Simultaneous and common cause failures due to lightning exposure generally do not have to be assumed for LCL B or C systems incorporating redundant, spatially separated installations in the aircraft. This is because aircraft transfer function tests and in-service experience have shown these redundant and spatially separated installations are not simultaneously exposed to the maximum lightning induced transients. For example, redundant systems (internal to the airframe) may mitigate lightning indirect effects, if there is acceptable separation between the equipment to prevent damage to multiple systems, so that the function is maintained. Therefore, simultaneous loss of all of these redundant and spatially separated LCL B or C systems due to lightning exposure does not need to be considered. However, if multiple LCL B or C systems including interface wiring are designed and installed within the same location in the aircraft, or share a common wiring connection, then the combined failure due to lightning exposure should be assessed to determine if the combined failures are catastrophic. If so, these systems should be designated as LCL A systems.
7.3.3.3 Failure Conditions. The lightning safety assessment should consider all potential adverse effects due to system failures, malfunctions, or misleading information. The lightning safety assessment may show that a system’s functions have different failure conditions in different phases of flight. Therefore, the system LCL corresponds to phase of flight with the most severe failure condition. For example, an automatic flight control system may have a catastrophic failure condition for autoland, while automatic flight control system operations in cruise may have a hazardous failure condition.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-136C and AMC 20-136A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source