FAA Advisory circularActive

AC 20-136C

Aircraft Electrical and Electronic System Lightning Protection

20-136C Source checked 2026-11-28

Scope, source and reading notes

Aircraft electrical and electronic system lightning protection for applicable Part 23, 25, 27, and 29 certification requirements.

Aerospace Consulting reference note: Describes a means of demonstrating lightning-protection compliance for aircraft systems; revision C supersedes AC 20-136B.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: a97137a34f9094ac10e6fb7caba11688edf5ab0b866ddf3d5ffa40f00e327cdd

Source page 10 · PDF page 10

6 BACKGROUND.

6.1 Regulatory Applicability. The standards for aircraft electrical and electronic system lightning protection are based on the aircraft's potential for lightning exposure and the consequences of system failure. The regulations require lightning protection of aircraft electrical and electronic systems with catastrophic, hazardous, or major failure conditions for aircraft certificated under 14 CFR parts 25, 27 and 29. The requirements also apply to 14 CFR part 23 airplanes approved for operations under instrument flight rules (IFR). Those part 23 (amendment 23-61) airplanes and part 27 rotorcraft, approved solely for operations under visual flight rules (VFR), require lightning protection of electrical or electronic systems that have catastrophic failure conditions.

6.2 Regulatory Requirements. Protection against the effects of lightning for aircraft electrical and electronic systems, regardless of whether these are ‘indirect’ or ‘direct’ effects of lightning, are addressed under §§ 23.1306 (amendment 23-61), 23.2515, 25.1316, 27.1316, and 29.1316. The terms ‘indirect’ and ‘direct’ are often used to classify the effects of lightning; however, the regulations do not, and are not intended to, differentiate between the effects of lightning. The focus is to protect aircraft electrical and electronic systems from the effects of lightning.

7 STEPS FOR SHOWING COMPLIANCE.

7.1 General.

7.1.1 The following steps describe a method for complying with §§ 23.1306 (amendment 23- 61) 23.2515, 25.1316, 27.1316, and 29.1316 requirements for your aircraft’s electrical and electronic systems. Adherence to the order of activities in the list below is not required.

• Identify the systems to be assessed.

• Perform a lightning safety assessment.

• Determine the lightning strike zones for the aircraft.

• Establish the aircraft lightning environment for each zone.

• Determine the lightning transient environment associated with the systems.

• Establish equipment transient design levels (ETDLs) and aircraft actual transient levels (ATLs).

• Verify compliance with the requirements.

• Take corrective measures, if needed.

Note: The steps above should be performed to address lightning transients induced in electrical and electronic system wiring and equipment, and lightning damage to aircraft external equipment and sensors that are connected to electrical and electronic systems,

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-136A

Related technical context

Engineering context
Evidence and scope

AC 20-136C and AMC 20-136A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.