FAA Advisory circularActive

AC 20-136C

Aircraft Electrical and Electronic System Lightning Protection

20-136C Source checked 2026-11-28

Scope, source and reading notes

Aircraft electrical and electronic system lightning protection for applicable Part 23, 25, 27, and 29 certification requirements.

Aerospace Consulting reference note: Describes a means of demonstrating lightning-protection compliance for aircraft systems; revision C supersedes AC 20-136B.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: a97137a34f9094ac10e6fb7caba11688edf5ab0b866ddf3d5ffa40f00e327cdd

Source page 43 · PDF page 43

AC 20-136C Appendix A

Normal Operation

The status where the system is performing its intended function.

Note: When addressing compliance with §§ 23.1306(a)(2) (amendment 23-61), 23.2515(a)(2), 25.1316(a)(2), 27.1316(a)(2), or § 29.1316(a)(2), the function whose failure is catastrophic (would prevent the continued safe flight and landing) should be in the same undisturbed state as before exposure to the lightning environment.

Timely Manner

The maximum allowable period for a system to reconfigure safely after a disruption.

Note: Timely recovery has been introduced to account for this period. The meaning of ‘in a timely manner’ depends on the function performed by the system being evaluated, the specific system design, the interactions between the system and the flight crew, and the phase of flight. The definition of ‘in a timely manner’ should be determined for each system and for the specific functions performed by the system. The applicable definition may be included in the lightning certification plan.

Transient Control Level (TCL)

The maximum allowable level of transients that appear at the equipment interface circuits because of the defined external environment.

Upset

Impairment of system operation, either permanent or momentary. For example, a change of digital or analog state that may or may not require a manual reset.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-136A

Related technical context

Engineering context
Evidence and scope

AC 20-136C and AMC 20-136A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.