MOC-5 SC-VTOL
Means of Compliance with SC-VTOL — Batch 5
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 5 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Fifth final batch, introducing additional means of compliance and amendments to earlier MoC batches. This is the final Issue 2, not the consultation draft or tracked copy.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 5e91110d91378ed3836aafe2cb30871f5b2d3802a92b97a28acf42913467a949
Doc. No: MOC-5 SC-VTOL Issue: 2 Date: 5 November 2026
Special Condition VTOL
Note A In general no considerations of the system architecture for an FDAL (IDAL) reduction are acceptable, as the FDAL classification in Table 1 already constitute a proportionate approach. An alleviation is granted to additional members as referred to in ED-135/ARP4761A Appendix P, where the following applies: For Category Basic 1 and 2, when at least two members of a functional failure set are contributing to a given failure condition they should be assigned at least the FDAL (IDAL) defined in Table 1. Other additional members should not be assigned lower than FDAL D (IDAL D).
Note D: The applicant is not expected to perform a quantitative analysis for minor failure conditions. It is underlined that a compliance statement is also expected in the SSAs or FHAs for those failure conditions.
Note:
Section 9. Safety Assessment Process (a), the following changes are introduced. Unchanged text is not reproduced for clarity. Changes are highlighted in blue colour for reader’s convenience.
[…]
Guidance on how to perform the Safety Assessment process can be found in ED-79B/ARP4754B and ED- 135/ARP4761A. […]
The depth and scope of the analyses are dependent on the system criticality and/or complexity. The Safety Objective Verification Approach should be defined in the Safety Program Plan: Guidance material derived from AMC 25.1309 Figure A2-2: Depth of Analysis Flowchart may be considered with the reservation that service experience is limited to the fleet of aircraft type(s) for which the applicant is the holder of the Type Certificate(s), the owner of the data, or, if accepted by EASA, has an agreement in place with the owner of the data that permits its use by the applicant for this purpose.
[…]
Any assumptions made during the safety assessment process need to be documented, justified and validated.
Note:
Section 9. Safety Assessment Process (b) Common mode considerations are fully replaced by the following. Changes are highlighted in blue colour for reader’s convenience.
Common mode analysis (CMA) is an analytical method to define independence principles and associated requirements, and verify that those independence requirements have been implemented sufficiently.
The CMA serves also as a tool to identify any lack of independence and to develop mitigation means to reduce the likelihood or the effect of a common mode failure resulting from a lack of independence. The CMA should be performed early in the safety assessment process, because it has an impact on the definition of the safety requirements as well as on the system architecture.
Sources of common mode failures include development, manufacturing, installation, maintenance, shared resource, event outside the system(s) concerned, etc. When identifying mitigation means for specific common modes, the means should be appropriate to the common mode failure/error.
It is important to note that even Items that are developed to IDAL A may be subject to development error. Such error may simultaneously affect several instances of the same item with potential functional or safety consequences. EASA has experienced cases, where a development error in IDAL A item has even resulted in
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC-5 SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source