EASA Means of ComplianceFinal — current published edition checked

MOC-5 SC-VTOL

Means of Compliance with SC-VTOL — Batch 5

Issue 2 — FINAL Source checked 2026-11-28

Scope, source and reading notes

Complete final batch 5 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.

Aerospace Consulting reference note: Fifth final batch, introducing additional means of compliance and amendments to earlier MoC batches. This is the final Issue 2, not the consultation draft or tracked copy.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 5e91110d91378ed3836aafe2cb30871f5b2d3802a92b97a28acf42913467a949

Source page 27 · PDF page 27

Doc. No: MOC-5 SC-VTOL Issue: 2 Date: 5 November 2026

Special Condition VTOL

(c) EWIS components located in areas of known moisture accumulation should be protected to minimize any

hazardous effects due to moisture.

(d) The design and installation of the wires should allow for a reasonable degree of deformation and

stretching without failure.

(e) For High Voltage (HV) EWIS, the following should be given consideration, though this list is not meant to be

complete:

(1) Minimize Partial discharge (PD).

PD can be defined as electrical discharges that occurs through the insulation between conductors or within the interstitial areas of a conductor’s insulation. Refer to SAE AIR7506 for additional guidance on addressing Partial Discharge.

(2) Minimize any Corona effect.

Corona is a form of partial discharge that occurs in gaseous media around conductors which are remote from solid or liquid insulation. Refer to SAE AIR7506 for additional guidance on addressing Corona Effect.

(3) Minimize mechanical effects.

Lorenz forces could add massive loads when not properly catered for in the installation.

5. System separation

(a) EWIS should be designed and installed with adequate physical separation from other EWIS, aircraft

systems and structural elements so that an EWIS component failure will not create a hazardous condition. Unless otherwise stated, for the purposes of this section, adequate physical separation should be achieved by separation distance or by a barrier that provides protection equivalent to that separation distance. The intent is to a perform a qualitative design assessment. Because each system design and VCA type can be unique, and because manufacturers have differing design standards and installation techniques, no mandatory specific separation distance can be given. Instead, an adequately chosen separation is required so that an EWIS component failure will not create a hazardous condition. Several factors should be considered when determining the separation distance, like for instance: (1) Electrical characteristics, amount of electrical power, and severity of failure condition of the system functions performed by the signals in the EWIS and adjacent EWIS. (2) The intended operating environment, including amount of deflection or relative movement possible and the effect of failure of a wire support or other separation means. (3) Possible EMI, HIRF, or induced lightning effects. The term “hazardous condition” as used in this document refers to severity of the effects of hazardous and catastrophic failure conditions as defined in MOC VTOL.2510 section 7 (a)(4) and (5). Unlike for a typical safety assessment as per VTOL.2510, here, no probability objectives are required for compliance. The intent of this section, is that the applicant must perform a qualitative design assessment of the installed EWIS and the physical separation to guard against hazardous conditions.

(b) EWIS should be designed and installed so that any electrical interference such as EMI likely to be present

in the aircraft will not result in hazardous effects upon the aircraft or its systems. Electromagnetic interference (EMI) can be introduced into aircraft systems and wiring by coupling between electrical cables or between cables and coaxial lines or other aircraft systems. Function of systems should not be affected by EMI generated by adjacent wire. EMI between wiring which is a source of EMI and wire susceptible to EMI increases in proportion to the length of parallel runs and decreases with greater

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

SC-VTOL-02

Related technical context

Engineering context
Evidence and scope

SC-VTOL-02 and MOC-5 SC-VTOL — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.