MOC-5 SC-VTOL
Means of Compliance with SC-VTOL — Batch 5
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 5 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Fifth final batch, introducing additional means of compliance and amendments to earlier MoC batches. This is the final Issue 2, not the consultation draft or tracked copy.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 5e91110d91378ed3836aafe2cb30871f5b2d3802a92b97a28acf42913467a949
Doc. No: MOC-5 SC-VTOL Issue: 2 Date: 5 November 2026
Special Condition VTOL
Lift/Thrust System Automatic Flight Guidance System Stall Warning System Airborne Collision Avoidance System (ACAS) Terrain Awareness Warning System (TAWS) Predictive Windshear System (PWS) Navigation Function
Energy storage and distribution System Landing Gear System (including extension/retraction, steering, braking, door locking, control and monitoring) Environmental Control System, when present On Ground/In Flight Determination System Ice Protection System
14) Effects of coexistence of air data parameters from different sources
Air data parameters obtained from primary Air Data System may coexist with other back up air data
derived from other sources (e.g., engine sensors, …). For example, back-up air data parameters may feed one or more primary flight displays, while air data parameters from primary ADS are in use by other aircraft systems. This coexistence of air data parameters needs to be assessed for impacts at the aircraft level. An analysis
should be carried out to identify those cases in which such coexistence triggers an effect at the aircraft level which is not consistent with the expected behaviour. Such effects may include, but are not limited to, the triggering of alerts, activation of protection modes
or inhibition of functions.
15) Human factor considerations
A human factor analysis should address the considerations developed in CM-SA-002 issue 02 or later.
when two or more air data system are present, this analysis should consider the effects of data mismatch
between the different air data systems as well as simultaneous and identical erroneous air data from the different systems The flight deck effects should assist the crew in determining the appropriate action to take. The
application of the crew actions should not result in excessive increase in crew’s workload and should not require exceptional piloting skill and alertness.
16) Limitations, Procedures, Instructions
The applicant should record the ADS maintenance instructions and mandatory maintenance tasks in the
Instruction for Continued Airworthiness (ICA), if any, in accordance with SC VTOL.2625 “instructions for continued airworthiness”. In cases where erroneous air data may be detected by the crew by reference to other independent
aircraft systems or reference to outside cues, the applicant should ensure crew procedures are provided in accordance with VTOL.2620 to direct the crew to take appropriate action. In cases where erroneous air data is detected by aircraft systems, care must be taken to ensure crew
procedures are assessed at aircraft-level to ensure that the crew is not overloaded by multiple system- level warnings.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC-5 SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source