Scope, source and reading notes
Complete final batch 5 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Fifth final batch, introducing additional means of compliance and amendments to earlier MoC batches. This is the final Issue 2, not the consultation draft or tracked copy.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 5e91110d91378ed3836aafe2cb30871f5b2d3802a92b97a28acf42913467a949
Doc. No: MOC-5 SC-VTOL Issue: 2 Date: 5 November 2026
Special Condition VTOL
separation. Wiring of sensitive circuits that may be affected by EMI should be routed away from other wiring interference or provided with sufficient shielding to avoid system malfunctions under operating conditions. EMI should be limited to negligible levels in wiring related to systems necessary for continued safe flight, landing, and egress.
(c) Wires and cables carrying heavy current (e.g. propulsion system feeder cables, energy storage output
lines, or charging interfaces) and their associated EWIS components should be designed and installed to ensure adequate physical separation and electrical isolation, so that damage to essential circuits will be minimized under fault conditions.
(d) EWIS associated with independent aircraft electrical power sources or electrical power sources connected
in combination should be designed and installed to ensure adequate physical separation and electrical isolation so that a fault in any one aircraft power source EWIS will not adversely affect any other independent power sources. In addition:
(1) Aircraft independent electrical power sources should not share a common ground terminating
location.
(2) Aircraft system’s static grounds should not share a common ground terminating location with any of
the aircraft’s independent electrical power sources.
This will help ensure the independence of separate electrical power sources so that a single ground failure will not disable multiple power sources and prevent introduction of unwanted interference into aircraft electrical power systems from other aircraft systems.
6. EWIS Safety Assessment
(a) Applicants should perform a system safety assessment to demonstrate compliance of the EWIS with
VTOL.2510. This assessment should be based on a qualitative approach, rather than being a numerical, probability-based quantitative analysis.
A traditional quantitative system safety assessment, focusing on the safety effects of failure conditions, is not considered adequate to properly identify the EWIS failures. Indeed, failure of an electrical wire, regardless of the safety effects of the failure of the associated system, could cause serious physical and functional damage to the aircraft, resulting in hazardous or even catastrophic failure conditions.
The integrated nature of wiring and the potential severity of its failures demand a more structured safety analysis approach than the one traditionally used. Traditional system safety assessments typically evaluate effects of wire failures on system functions. But they do not consider physical wire failure as a cause of the failure of other wires within the EWIS. Traditional assessments look at external factors like e.g. rotor burst, lightning, but not at internal factors, like a single wire chafing or arcing event, as the cause of the failure of functions supported by the EWIS. In order to demonstrate compliance of the EWIS with VTOL.2517, it is expected that those failure modes are addressed at the aircraft level. This means that EWIS failures should be analysed to determine what effect they could have on the safe operation of the aircraft.
As specified above, the analysis required to demonstrate compliance of the EWIS with VTOL.2510 is based on a qualitative approach. The intent is not to examine each individual wire and its relation to other wires. It is rather to ensure that there are no combinations of failures that could lead to a hazardous condition. However, in case such analysis process determines that a failure in a given bundle may lead to a
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.