Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 5 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Fifth final batch, introducing additional means of compliance and amendments to earlier MoC batches. This is the final Issue 2, not the consultation draft or tracked copy.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 5e91110d91378ed3836aafe2cb30871f5b2d3802a92b97a28acf42913467a949
Doc. No: MOC-5 SC-VTOL Issue: 2 Date: 5 November 2026
Special Condition VTOL
MOC – SUBPART D – DESIGN AND CONSTRUCTION
MOC 2 VTOL.2300 Acceptability of ASTM standard F3232/F3232M-20 for Fly-by-Wire flight control systems
Note:
§5.1 is removed from the table of accepted paragraphs as this requirement does not relate to Flight Controls but Flight Guidance Systems.
MOC 5 VTOL.2300 Hidden Failures in Fly-by-Wire flight control systems
Note:
The following text fully replaces MOC 5 VTOL.2300 in Doc. No. MOC SC-VTOL Issue 2, dated 12 May 2021. Changes and additions are highlighted in blue colour for the reader’s convenience.
To demonstrate compliance with VTOL.2300, in line with VTOL.2510, and to reach an acceptable level of safety, specific attention should be paid to latent failures.
The objective is to obtain a design with a minimum number of significant latent failures. Each significant latent failure should be highlighted in the system safety assessment and subject to review by EASA.
In addition to the general considerations in Section 12 of MOC VTOL.2510, the following applies for fly-by-wire flight control systems:
(a) Definitions:
Latent = dormant = hidden for more than one flight. A failure is latent until it is made known to the flight crew or maintenance personnel. A significant latent failure is one, which would in combination with one or more specific failures, or events result in a Hazardous or Catastrophic Failure Condition. A significant failure condition is one which is classified Hazardous or Catastrophic and contains one or more significant latent failures.
(b) The following approach should be followed:
Double failures, with either one latent, that can lead to a Catastrophic Failure Condition should be avoided as far as practicable in system design. Deviations should be presented and accepted by EASA. Latent failures that contribute to Hazardous or Catastrophic effects at aircraft level should be avoided in system design. The use of periodic maintenance or flight crew checks to detect significant latent failures when they occur is undesirable and should not be used in lieu of practical and reliable failure monitoring and indications. It is recognised that, on occasion, it would be impracticable to meet (1) and (2). In such cases:
(i) The remaining latent failures should be recorded and justified in the PSSA/SSA and
reviewed during the design review process for compliance,
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.