MOC-5 SC-VTOL
Means of Compliance with SC-VTOL — Batch 5
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 5 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Fifth final batch, introducing additional means of compliance and amendments to earlier MoC batches. This is the final Issue 2, not the consultation draft or tracked copy.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 5e91110d91378ed3836aafe2cb30871f5b2d3802a92b97a28acf42913467a949
Doc. No: MOC-5 SC-VTOL Issue: 2 Date: 5 November 2026
Special Condition VTOL
Note: VTOL.2510(a)(3) is not considered applicable for the EWIS. The EWIS safety assessment consists in a holistic qualitative analysis at aircraft level. It complements the quantitative approach already used to demonstrate compliance of related systems and equipment with VTOL.2510. Extending such qualitative analysis to address also Major failure conditions of the EWIS would lead to a level of complexity that is not deemed commensurate with the safety benefit that could be potentially obtained.
7. Component identification
EWIS components should be labelled or otherwise identified using a consistent method that facilitates identification of the EWIS component, its function, and its design limitations, if any.
8. Fire protection
In reference to VTOL.2325 and VTOL.2330:
(a) EWIS components that are located in designated fire zones and are necessary during emergency
procedures should be at least fire resistant.
(b) Insulation on electrical wire and electrical cable, and materials used to provide additional protection for
the wire and cable, installed in any area of the aircraft, should be self-extinguishing when tested in accordance with the applicable portions of Appendix F of CS 25.
9. Electrical bonding and protection against static electricity
On aircraft having grounded electrical systems, electrical bonding provided by EWIS components should provide an electrical return path capable of carrying both normal and fault currents without creating a shock hazard or damage to the EWIS components, other aircraft system components, or aircraft structure.
10. Occupant protection
All occupants should be protected from hazards of the electrical systems. The accessible EWIS should be readily identifiable and visible to the occupants and rescue personnel, especially during egress situations and meet the requirements of VTOL.2320.
11. Circuit protective devices
Electrical wires and cables should be designed and installed so they are compatible with the circuit protection devices that ensure compliance with VTOL.2525, and VTOL.2510, so that a fire or smoke hazard cannot be created under temporary or continuous fault conditions.
12. Accessibility provisions
Access to EWIS should be provided to allow for inspection and replacement of any EWIS component as necessary for continued airworthiness.
13. Protection of EWIS
(a) EWIS should be designed and installed to minimize damage and risk of damage to EWIS by movement of
people in the aircraft during all phases of flight, maintenance, and servicing.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC-5 SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source