CS-27
Small Rotorcraft
Amendment 10; corrected 15 September 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-27 Amendment 10, including AMC, GM and appendices.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for small rotorcraft, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: e762c494818f5badf2cceb0a8dc04e8cf5938efa2552deeadc0f708d1ead92ae
protection compared to that offered by the seat if it were installed directly on the helicopter existing floor seat track and floor construction. For an adapter plate to be considered sufficiently integrated to be part of the floor, the adapter plate should be capable of accommodating floor deformation and be able to safely react and distribute the seat loads into the rotorcraft.
(d) Seat adapter plate definition and classification
(1) Definitions
The definitions of plinth and pallet that are available in AC 25.562(b) are valid.
In general, swivelling seat adapter plate systems are by definition considered to be plinths.
(2) Classification
There are three possible options for the seat-to-floor interface with corresponding means of compliance. In each case, the applicant is requested to show that any interface between the existing floor and the seat will not create a weaker element between the seat and the existing airframe than that that would exist for a CS 27.562-compliant seat attached directly to the standard floor, e.g. seat track.
Acceptable means of assessing seat installations using adapter plates:
Option 1
— The adapter is classified as a plinth following AC 25.562-1B.
— Compliance with CS 27.561 and CS 27.562 must be shown.
— The plinth must be tested as part of the seat according to CS 27.562(b)(1) and (b)(2)
unless alternative compliance is agreed as per CS 27.562(d).
— The guidance of AC 25.562-1B and AMC 27.307 may be used to reduce the number
of tests based on design similarity.
Option 2
— The adapter is classified as a pallet due to its size following AC 25.562-1B.
— The seat and its attachments to the pallet only are tested according to CS 27.562
and CS 27.561.
— The pallet is justified against CS 27.561 only.
Option 3
— If neither Option 1 nor 2 clearly apply, seat-to-floor interface structure may be
proposed to be classified as an integral part of the floor based on one of the methods described below.
— If classification as part of the floor is agreed with the Agency, the seat and its
attachments to the structure are tested according to CS 27.562 and compliance with CS 27.561 is shown for the whole installation.
Acceptable methods to be used in support of Option 3, allowing classification of the new seat-to-floor interface structure as an integral part of the floor structure:
Method 1
A design review showing the floor design for seat installation uses the same or an equivalent design principle as the current floor provided in the type design. If the pre-
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-27 and AC 27-1B — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source