CS-27
Small Rotorcraft
Amendment 10; corrected 15 September 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-27 Amendment 10, including AMC, GM and appendices.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for small rotorcraft, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: e762c494818f5badf2cceb0a8dc04e8cf5938efa2552deeadc0f708d1ead92ae
(3) There must be means to warn the crew when any heater, the heat output of which is essential for safe operation, has been shut off by the automatic means prescribed in sub- paragraph (g)(1).
(h) Air intakes. Each combustion and heat-ventilating air intake must be located so that no flammable fluids or vapours can enter the heater system:
(1) During normal operation; or
(2) As a result of the malfunction of any other component.
(i) Heater exhaust. Each heater exhaust system must meet the requirements of CS 27.1121 and 27.1123.
(1) Each exhaust shroud must be sealed so that no flammable fluids or hazardous quantities of vapours can reach the exhaust system through joints.
(2) No exhaust system may restrict the prompt relief of any backfire that, if so restricted, could cause heater failure.
(j) Heater fuel systems. Each heater fuel system must meet the powerplant fuel system requirements affecting safe heater operation. Each heater fuel system component in the ventilating airstream must be protected by shrouds so that no leakage from those components can enter the ventilating airstream.
(k) Drains. There must be means for safe drainage of any fuel that might accumulate in the combustion chamber or the heat exchanger.
(1) Each part of any drain that operates at high temperatures must be protected in the same manner as heater exhausts.
(2) Each drain must be protected against hazardous ice accumulation under any operating condition.
CS 27.861 Fire protection of structure, controls, and other parts
Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by powerplant fires must be fireproof or protected so they can perform their essential functions for at least 5 minutes under any foreseeable powerplant fire conditions.
CS 27.863 Flammable fluid fire protection
(a) In each area where flammable fluids or vapours might escape by leakage of a fluid system, there must be means to minimise the probability of ignition of the fluids and vapours, and the resultant hazards if ignition does occur.
(b) Compliance with sub-paragraph (a) must be shown by analysis or tests, and the following factors must be considered:
(1) Possible sources and paths of fluid leakage, and means of detecting leakage.
(2) Flammability characteristics of fluids, including effects of any combustible or absorbing materials.
(3) Possible ignition sources, including electrical faults, over-heating of equipment, and malfunctioning of protective devices.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.