CS-27
Small Rotorcraft
Amendment 10; corrected 15 September 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-27 Amendment 10, including AMC, GM and appendices.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for small rotorcraft, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: e762c494818f5badf2cceb0a8dc04e8cf5938efa2552deeadc0f708d1ead92ae
(d) Open problem report management
This AMC recognises AMC 20-189 as an acceptable means of compliance for establishing an open problem report management process for the system, software and AEH domains.
Integrated Modular Avionics (IMA)
This AMC recognises AMC 20-170 as an acceptable means of compliance for development and integration of IMA.
[Amdt 27/10]
CS 27.1316 Electrical and electronic system lightning protection
(a) Each electrical and electronic system that performs a function whose failure would prevent the continued safe flight and landing of the rotorcraft must be designed and installed in a way that:
(1) the function is not adversely affected during and after the rotorcraft’s exposure to lightning; and
(2) the system automatically recovers normal operation of that function in a timely manner after the rotorcraft’s exposure to lightning unless the system’s recovery conflicts with other operational or functional requirements of the system that would prevent continued safe flight and landing of the rotorcraft.
(b) For rotorcraft approved for instrument flight rules operation, each electrical and electronic system that performs a function whose failure would reduce the capability of the rotorcraft or the ability of the flight crew to respond to an adverse operating condition must be designed and installed in a way that the function recovers normal operation in a timely manner after the rotorcraft’s exposure to lightning.
[Amdt 27/4]
CS 27.1317 High-Intensity Radiated Fields (HIRF) protection
(a) Each electrical and electronic system that performs a function whose failure would prevent the continued safe flight and landing of the rotorcraft must be designed and installed in a way that:
(1) the function is not adversely affected during and after the rotorcraft’s exposure to HIRF environment I as described in Appendix D;
(2) the system automatically recovers normal operation of that function in a timely manner after the rotorcraft’s exposure to HIRF environment I as described in Appendix D unless the system’s recovery conflicts with other operational or functional requirements of the system that would prevent continued safe flight and landing of the rotorcraft;
(3) the system is not adversely affected during and after the rotorcraft’s exposure to HIRF environment II as described in Appendix D; and
(4) each function required during operation under visual flight rules is not adversely affected during and after the rotorcraft’s exposure to HIRF environment III as described in Appendix D.
(b) Each electrical and electronic system that performs a function whose failure would significantly reduce the capability of the rotorcraft or the ability of the flight crew to respond to an adverse operating condition must be designed and installed in a way that the system is not adversely
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-27 and AC 27-1B — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source