CS-27
Small Rotorcraft
Amendment 10; corrected 15 September 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-27 Amendment 10, including AMC, GM and appendices.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for small rotorcraft, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: e762c494818f5badf2cceb0a8dc04e8cf5938efa2552deeadc0f708d1ead92ae
This implies the need of a comprehensive assessment of the external loads (addressed by CS 27.301), the resulting internal strains and stresses, and the structural allowables.
CS 27.307 requires compliance for each critical loading condition. Compliance may be shown by analysis supported by previous test evidence, analysis supported by new test evidence or by test only. As compliance by test only is impractical in most cases, a large portion of the substantiating data will be based on analysis.
There are a number of standard engineering methods and formulas which are known to produce acceptable, often conservative, results especially for structures where load paths are well defined.
Those standard methods and formulas, applied with a good understanding of their limitations, are considered to be reliable analyses when demonstrating showing compliance with CS 27.307. Conservative assumptions may be considered in assessing whether or not an analysis may be accepted without test substantiation.
The application of methods such as the finite element method or engineering formulas to complex structures in modern aircraft is considered to be reliable only when validated by full- scale tests (ground and/or flight tests). Experience relevant to the product in the utilisation of such methods should be considered.
(e) Classification of structure
(a) The structure of the product should be classified into one of the following three categories:
(1) new structure
(2) similar new structure
(3) derivative/similar structure
(b) Justifications should be provided for classifications other than new structure. Elements that should be considered are:
(1) the accuracy/conservatism of the analytical methods; and
(2) the comparison of the structure under investigation with a previously tested structure.
Considerations should include but are not limited to the following:
— external loads (bending moment, shear, torque, etc.);
— internal loads (strains, stresses, etc.);
— structural design concepts such as details, geometry, structural arrangements, load
paths;
— materials;
— test experience (load levels achieved, lessons learned);
— deflections;
— deformations;
— extent of extrapolation from test stress levels.
(f) Need and extent of testing
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-27 and AC 27-1B — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source