FAA Advisory circularActive

AC 29-2C

Certification of Transport Category Rotorcraft

29-2C — Changes 1–9 incorporated (2023-06-23) Source checked 2026-11-28

Scope, source and reading notes

Transport category rotorcraft certification guidance under Part 29; consolidated FAA publication incorporating Changes 1 through 9. Base publication catalog date: 2008-09-30; latest included change: 2023-06-23.

Aerospace Consulting reference note: Broad Part 29 guidance covering transport rotorcraft design, flight, equipment, systems, and certification, including system safety and flight guidance.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c57691386dd1e59263633bd8fdaabb842a958061a9b6a82d30dad18358977013

Source page 322 · PDF page 322

to develop a consistent ΔKth database and the use of published data may require additional conservatism.

(8) Inspection Intervals. Each of the following three methods provides a means to establish inspection intervals for detectable damage or detectable damage growth. The time of the first inspection should coincide with the repetitive interval established unless the applicant can substantiate an alternate time.

(i) Safe-Life Inspection for a CDF provides a safe interval of operation between repetitive inspections for the presence of probable detectable flaws. The substantiation is accomplished by testing and analysis employing conventional Safe-Life methodology except that intrinsic and discrete critical flaws are considered. The size of flaws considered should be “clearly detectable”, which is intended to be a conservative representation of detectable flaws that could remain in place for the entire interval in spite of routine inspections for general condition. It should be noted that this method, since it is a Safe-Life (crack initiation) method, is not appropriate for use when the flaw being considered is already a crack.

(A) The method described in paragraph f.(7)(iii), Safe-Life Retirements with Clearly Detectable Flaws, may be employed for this case, except that the calculated retirement time is used as a repetitive inspection interval.

(B) The repetitive inspection consists of examination of the structure for the presence of the flaw using the substantiated inspection method. If no flaw is found, the structure may be returned to service for another inspection interval period, up to the established retirement time. If the flaw is found, the structure is retired; or, if a repair procedure for the specific flaw type has been substantiated, the structure is repaired and returned to service for another inspection interval period, up to the established retirement time for the structure.

(C) Substantiation of repairs should include careful consideration as to whether undetectable cracks may now exist and whether the original certification approach is still applicable.

(ii) Crack Growth Inspection. This approach depends on detection of cracks before they become critical to ensure the continued airworthiness of a PSE. While any inspections that are capable of detecting cracks with high reliability may be used with this approach, the criteria stated in paragraph f.(6), Inspectability and Inspection Methods, should be considered in making the selection. The inspection method chosen will define the initial inspectable crack that will be used to perform the fatigue tolerance evaluation. Once the initial inspectable crack is defined, crack growth, and residual strength assessments must be performed to determine the time for the initial inspectable crack (aDET) to grow to a size (aCRIT) that would result in a catastrophic failure of the rotorcraft if limit loads were applied. This assessment could be theoretically done analytically or by test; however, in most cases it is performed analytically using fracture mechanics methods. The resulting life for aDET to grow to

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 27-1B

Related technical context

Engineering context
Evidence and scope

AC 27-1B and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source
CS-29

Related technical context

Engineering context
Evidence and scope

CS-29 and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.