AC 29-2C
Certification of Transport Category Rotorcraft
29-2C — Changes 1–9 incorporated (2023-06-23) Source checked 2026-11-28
Scope, source and reading notes
Transport category rotorcraft certification guidance under Part 29; consolidated FAA publication incorporating Changes 1 through 9. Base publication catalog date: 2008-09-30; latest included change: 2023-06-23.
Aerospace Consulting reference note: Broad Part 29 guidance covering transport rotorcraft design, flight, equipment, systems, and certification, including system safety and flight guidance.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c57691386dd1e59263633bd8fdaabb842a958061a9b6a82d30dad18358977013
Lr
LP
Failure of Secondary Load Path at Limit Load
Failure of Primary Load Path Under Inservice Loads
CRACK SIZE
Crack Growth in Primary Load Path Crack Growth in Secondary Load Path after Primary Load Path Failure
aDET
Crack Growth in Secondary Load Path with Primary Load Path Intact
Dai
ai
NF
CRACK GROWTH LIFE
Figure AC 29.571B-8: Multiple Load Path Structure Analytical Evaluation to Support Inspection for Less than a Failed Load Path.
(C) Safety Factors.
(1) In determining the factor of N to be used for determining the inspection time, consideration should be given to the crack growth data used (e.g., top of scatter data versus average data, number of specimens used to generate data, etc.) and the capability of the inspection procedure.
(2) The minimum suggested N value should be N=2 in the case where the conservative top-of-scatter crack growth data are used in the crack growth analysis, or N=4 when the average crack growth data are used in the crack growth analysis, or when the crack growth life is obtained from the crack growth test of one specimen (for two or more full scale specimens, N=3 of the shortest crack growth life can be used).
(iii) Safe-Life Inspection for a Failed Element.
(A) A Safe-Life Inspection substantiation for a Failed Load Path provides a safe interval of operation between repetitive inspections for the failed load path. The substantiation is accomplished by testing and analysis employing conventional Safe-Life methodology except that the configuration of the structure substantiated is with the
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 27-1B and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting sourceRelated technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source