FAA Advisory circularActive

AC 29-2C

Certification of Transport Category Rotorcraft

29-2C — Changes 1–9 incorporated (2023-06-23) Source checked 2026-11-28

Scope, source and reading notes

Transport category rotorcraft certification guidance under Part 29; consolidated FAA publication incorporating Changes 1 through 9. Base publication catalog date: 2008-09-30; latest included change: 2023-06-23.

Aerospace Consulting reference note: Broad Part 29 guidance covering transport rotorcraft design, flight, equipment, systems, and certification, including system safety and flight guidance.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c57691386dd1e59263633bd8fdaabb842a958061a9b6a82d30dad18358977013

Source page 313 · PDF page 313

(H) Critical areas will be assumed as a typical location of the damage, unless proper justification is provided to limit the applicability to specific areas or sections of the part.

(iii) Classification of Damage.

(A) The results of the threat assessment are used to classify the damage used in the fatigue tolerance evaluation. The process employed to classify the damage will depend on the fatigue tolerance evaluation method to be used. Depending on the method, a BDF, a CDF, a BEC, or an initial inspectable crack must be established.

(B) For each damage type identified, the sizes to be considered should be representative of the maximum sizes that might not be detected by the inspection techniques established for the component. Sizes exceeding those that are likely to occur do not need to be considered. Standard sizes of damage or standard level of aggression may be derived from previous experience. Each applicant will be required to present justification for damage and crack sizes to be used in the fatigue tolerance evaluations. Within the operational life, defect sizes that have been found in service should be correlated with the sizes used in the design certification.

(C) Barely Detectable Flaw (BDF). For retirement time analysis, flaw sizes that are “barely detectable” may be used to conservatively represent the worst case of undetectable flaws. Alternatively, when the detectable size is larger than the one identified by the threat assessment, a smaller size, but one not less than the flaw size likely to occur, can be used. Sometimes an “allowable” detectable size is established as acceptable for a specific manufacturing process, such as castings, to remain in place for the life of the structure. When it is impossible to simulate that maximum allowable size in the test specimen, the sizes available in the specimen may be used, provided the subsequent analysis of the test result conservatively accounts for the shortfall in the damage size.

(D) Clearly Detectable Flaw (CDF). For inspection intervals, flaw sizes that are “clearly detectable” may be used. The largest discrete size of a CDF to be considered may be limited to the maximum size of the CDF that is likely to remain in place for a significant period of time and not be detected during routine inspections for general conditions and normal observations by knowledgeable personnel. The damage size used may be limited to the maximum probable size identified in the threat assessment. For multiple load path structure, the number of failed load paths to be considered should be established.

(E) Bounding Equivalent Crack (BEC). A Bounding Equivalent Crack must be defined to determine a retirement time using the Crack Growth Retirement method. The size of the BEC should bound the life reducing effect of damage that could occur as a result of manufacturing, maintenance, or the service environment. The size may be established by analytical back calculations from coupon or service fatigue life data accounting for material variability effects in the data. In any case, there should be no

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 27-1B

Related technical context

Engineering context
Evidence and scope

AC 27-1B and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source
CS-29

Related technical context

Engineering context
Evidence and scope

CS-29 and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.