AC 29-2C
Certification of Transport Category Rotorcraft
29-2C — Changes 1–9 incorporated (2023-06-23) Source checked 2026-11-28
Scope, source and reading notes
Transport category rotorcraft certification guidance under Part 29; consolidated FAA publication incorporating Changes 1 through 9. Base publication catalog date: 2008-09-30; latest included change: 2023-06-23.
Aerospace Consulting reference note: Broad Part 29 guidance covering transport rotorcraft design, flight, equipment, systems, and certification, including system safety and flight guidance.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c57691386dd1e59263633bd8fdaabb842a958061a9b6a82d30dad18358977013
used in the future to perform some required function or to allow required maintenance to be predicated on the operation of the system. This consideration becomes particularly important if the system is software based. A further discussion of system software is included in paragraph b.(19)(iii)(B) below. Refer to section AC 29 MG 15 of this AC for guidance on certification of these systems, also referred to as Health Usage Monitoring Systems (HUMS).
(ii) System Installation. Show that system installations are free from hazards for both normal operation and possible malfunctions. Malfunctions which might be caused by software errors are discussed under paragraph b.(19)(iii)(B) below. The accuracy and response of the monitoring device or system should be sufficient to allow the operational and maintenance personnel to relate the data obtained to required maintenance actions. Use the exceedance (engine limit) information acquired by these systems in place of information previously acquired from field reports of operational personnel utilizing the basic aircraft instruments. In this case, the automated system will generally produce results, which are more accurate than the basic aircraft instruments. However, in this circumstance, it is not appropriate to require the monitor system to be more accurate than the previously approved methods used to provide the required exceedance data. If the data collected by the system require filtering prior to use, it is equally acceptable to accomplish this filtering either as the data are being acquired (airborne function) or when the data are analyzed (ground based function) and used in the maintenance of the rotorcraft.
(iii) System Components.
(A) Hardware. The hardware of the system, when operating under the control of the imbedded software, should be shown to comply with § 29.1301. Additionally, in showing compliance to § 29.1309(a), laboratory testing to the appropriate portions of RTCA Document DO-160 (current version) should be performed.
(B) Software. If the function of the monitor system depends on embedded airborne software to determine all or part of its functioning, RCTA Document DO-178 (current version) is the recommended standard to be used for the approval of the system software. A further discussion of the use of this document is included in section 29.1309 of this AC. Carefully consider the selection of the software level because system approval is sometimes initially sought on the basis of the system being a non-required optional system. Further, if there is no dependence on the system software to preclude a hazardous failure mode, then a low software level would be acceptable. However, once initially certificated, it is very difficult to qualify software to higher levels of “quality.” Because of this, we recommend choosing the software at a level consistent with that of the ultimate use for the planned system approval. If the system approval is only to be as non-required optional equipment, then the choice of a low level of software qualification may be appropriate. However, when more experience is gained with the operation of the system, and it is ultimately planned to seek approval to perform required functions, then an appropriate higher level of software should be initially obtained.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 27-1B and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting sourceRelated technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source