FAA Advisory circularActive

AC 29-2C

Certification of Transport Category Rotorcraft

29-2C — Changes 1–9 incorporated (2023-06-23) Source checked 2026-11-28

Scope, source and reading notes

Transport category rotorcraft certification guidance under Part 29; consolidated FAA publication incorporating Changes 1 through 9. Base publication catalog date: 2008-09-30; latest included change: 2023-06-23.

Aerospace Consulting reference note: Broad Part 29 guidance covering transport rotorcraft design, flight, equipment, systems, and certification, including system safety and flight guidance.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c57691386dd1e59263633bd8fdaabb842a958061a9b6a82d30dad18358977013

Source page 523 · PDF page 523

by the pilot from a primary control or, after a command is given by the pilot, by a crewmember from a remote location. Additional safety precautions (such as a lockwire) should be considered for remote hoist console in the cabin. Any emergency release function provided by a remote hoist console must also be designed to protect against inadvertent activation during the hoist operation. If the backup DAD is a cable cutter, it should be properly secured, placarded and readily accessible to the crewmember intended to use it.

(vii) Section 29.865(b)(3)(ii) Electromagnetic Interference. Protection of the QRS against potential internal and external sources of electromagnetic interference (EMI) and lightning is required. This is necessary to prevent inadvertent load release from sources such as lightning strikes, stray electromagnetic signals, and static electricity.

(A) Jettisonable NHEC systems should be able to absorb a minimum of 20 volts per meter (i.e., CAT U) radio-frequency (RF) field strength per RTCA Document DO-160.

(B) Jettisonable HEC systems should be able to absorb a minimum of 200 volts per meter (i.e., CAT Y) RF field strength per RTCA Document DO-160.

Notes: (1)These RF field threat levels may need to be increased for certain special applications such as microwave tower and high voltage high line repairs. Separate criteria for special applications under multi-agency regulation (such as IEEE or OSHA standards) should also be addressed, as applicable, during certification. When necessary, the issue paper process can be used to establish a practicable level of safety for specific high voltage or other special application conditions. The helicopter HIRF safety assessment should consider the effects on helicopter flight safety due to a HIRF-induced failure or malfunction of external load systems, such as uncommanded hoist winch activation without ability to jettison, or uncommanded load jettison. The appropriate failure effect classification should be assigned based on this assessment, and compliance demonstrated according to § 29.1317 and AC 20-158. This requirement should not be limited to the cable cutter devices or load jettison subsystems only. In some designs, uncommanded load release or hoist winch activation could also result from a failure of the command and control circuits of the system.

(2) An approved standard rotorcraft test, which includes the full HIRF frequency and amplitude external and internal environments, on the QRS and any applicable PCDS, or the entire rotorcraft including the QRS and any applicable PCDS, could be substituted for the jettisonable NHEC and HEC systems tests as long as the RF field strengths directly on the QRS and PCDS are shown to equal or exceed those defined by paragraphs d.(7)(vii)(A) and d.(7)(vii)(B) for NHEC and HEC respectively.

(3)The EMI levels specified in paragraphs d.(7)(vii)(A) and d.(7)(vii)(B) of this guidance are total EMI levels to be applied to the QRS (and affected QRS component) boundary. The total EMI level applied should include the effects of both

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 27-1B

Related technical context

Engineering context
Evidence and scope

AC 27-1B and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source
CS-29

Related technical context

Engineering context
Evidence and scope

CS-29 and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.